Far-UVC Radiation for Disinfecting Hands or Gloves?
Open Access
Abstract
(1) Background: Far-UVC radiation in the spectral range 200–230 nm has, according to previous findings, a strong antimicrobial effect on pathogens, but exhibits hardly any harmful effect on human skin. Therefore, the present study will discuss whether such radiation could also be suitable for hand disinfection in the healthcare sector. (2) Methods: Hands and gloves were microbially contaminated and exposed to radiation from a 222 nm krypton-chloride-excimer lamp. The applied doses were 23 mJ/cm2 and 100 mJ/cm2, respectively. Irradiated and non-irradiated hands and gloves were pressed onto agar plates and colonies were counted and compared after 24 h of incubation. For comparison, we also treated hands and gloves with a commercial liquid alcohol-based disinfectant. (3) Results: On the hand, the 23 mJ/cm2 resulted in the reduction of the observed colonies on the agar plates by one log level. For the gloves irradiated with 100 mJ/cm2, a colony reduction of 1.3 log levels was recorded. In the comparative experiments with the commercial disinfectant, a colony reduction of 1.9 and approximately one log level was observed on hand and gloves, respectively. (4) Conclusion: In both cases, far-UVC radiation provided a considerable reduction in microorganisms. However, compared to published far-UVC irradiation results in suspensions, the disinfection success on hands and gloves was rather low. With regard to the irradiation limits currently existing in the European Union, multiple daily hand disinfection with far-UVC radiation is actually legally not possible at present, but the thresholds are currently under discussion and could change in the future. Far-UVC disinfection of hands in gloves seems theoretically possible if attention is paid to potential perforations in the gloves.Keywords
This publication has 18 references indexed in Scilit:
- A Need to Revise Human Exposure Limits for Ultraviolet UV‐C Radiation†Photochemistry and Photobiology, 2021
- Extreme Exposure to Filtered Far‐UVC: A Case Study†Photochemistry and Photobiology, 2021
- Exposure of Human Skin Models to KrCl Excimer Lamps: The Impact of Optical Filtering†Photochemistry and Photobiology, 2021
- Minimal, superficial DNA damage in human skin from filtered far‐ultraviolet CBritish Journal of Dermatology, 2021
- What is new with hand hygiene?Current Opinion in Infectious Diseases, 2020
- Long‐term Effects of 222‐nm ultraviolet radiation C Sterilizing Lamps on Mice Susceptible to Ultraviolet RadiationPhotochemistry and Photobiology, 2020
- Händehygiene in Einrichtungen des GesundheitswesensBundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz, 2016
- Hand hygiene monitoring technology: a systematic review of efficacyJournal of Hospital Infection, 2015
- The Effects of UV Irradiation and Gas Plasma Treatment on Living Mammalian Cells and Bacteria: A Comparative ApproachIEEE Transactions on Plasma Science, 2004
- Recommendations for surgical hand disinfection—requirements, implementation and need for research. A proposal by representatives of the SFHH, DGHM and DGKH for a European discussionJournal of Hospital Infection, 2002