Incinerator Flue Gas Cleaning Using Wet-Type Electrostatic Precipitator.
- 1 January 2000
- journal article
- Published by Taylor & Francis in JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
- Vol. 33 (4) , 669-674
Abstract
An experimental approach has been adopted to remove dioxins and other pollutants from incinerator flue gas in a pilot-scale experimental system. The main objective of this study is to investigate the combined system for simultaneous removal of gaseous pollutants and dusts. The combined gas cleaning system consists of a radiator, a scrubber and a wet-type electrostatic precipitator (ESP). Dioxins can be decomposed effectively using after-burners downstream of the incinerator by maintaining the gas temperature around 850 ± 20°C. Fractional removal rates for various kinds of dioxins (PCDDs + PCDFs) were measured in this study. When the combined system is used, dioxin removal rates of 90–92% are achieved over a wide range of initial concentrations of dioxins. The combined system is also found to be effective in the removal of NOx, SOx, HCl, and dust.Keywords
This publication has 2 references indexed in Scilit:
- Semipilot plant pulse energized cold-precharger electrostatic precipitator tests for collection of moderately high resistivity flyash particlesIEEE Transactions on Industry Applications, 1996
- Reactive absorption of NOx using wet discharge plasma reactorIEEE Transactions on Industry Applications, 1995