Personal neutron dosimetry in nuclear power plants using etched track and albedo thermoluminescence dosemeters
Authors:
- F. FernandezFFF. Fernandez
- M. BakaliMBM. Bakali
- K. AmgarouKAK. Amgarou
- A. NourreddineANA. Nourreddine
- D. MouhssineDMD. Mouhssine
- 1 August 2004
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 110 (1-4) , 701-704
Abstract
Measurement of the personal dose equivalent rates for neutrons is a difficult task because available dosemeters do not provide the required energy response and sensitivity. Furthermore, the available wide calibration spectra recommended by the International Standard Organisation does not reproduce adequately the spectra encountered in practical situations of the nuclear industry. There is a real necessity to characterise the radiation field, in which workers can be exposed, and to calibrate personal dosemeters in order to determine the dose equivalent in these installations. For this reason, we measure the neutron spectrum with our Bonner sphere system and we fold this spectrum with energy-dependent fluence-to-dose conversion coefficients to obtain the reference dose equivalent rate. This reference value is then compared with the personal dosemeter reading to determine a field-specific correction factor. In this paper, we present the values of this field-specific correction factor for etched track and albedo thermoluminescence dosemeters at three measurement locations inside the containment building of the Vandellòs II nuclear power plant. We have found that assigning to each personal dosemeter the mean value of the field-specific correction factors of the three measurement locations, allows the evaluation of neutron personal dose equivalent rate with a relative uncertainty of ∼25 and 15% for the PADC and albedo dosemeters, respectively.Keywords
This publication has 5 references indexed in Scilit:
- MITOM: a new unfolding code based on a spectra model method applied to neutron spectrometryRadiation Protection Dosimetry, 2004
- The importance of the direction distribution of neutron fluence, and methods of determinationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- Monte Carlo calculations and experimental results of Bonner spheres systems with a new cylindrical Helium-3 proportional counterNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- A Dosemeter Based on Nuclear Track Etched Detectors for Thermal, Fast and High Energy Neutrons with Flat ResponseRadiation Protection Dosimetry, 1999
- Progress on Calibration Procedures with Realistic Neutron SpectraRadiation Protection Dosimetry, 1995