Heart rate detection using single-channel Doppler radar system
Authors:
- 11 July 2022
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2022, 1953-1956
Abstract
A number of algorithms have been developed to extract heart rate from physiological motion data with the Doppler radar system. Yet, it is very challenging to elimi-nate the noise associated with surroundings, especially with a single-channel Doppler radar system. However, single-channel Doppler radars provide the advantage of operating at lower power. Additionally, the heart rate extraction using single-channel Doppler radar has remained somewhat unexplored. This has motivated us to develop effective signal processing algorithms for signals received from single-channel Doppler radars. In this paper, we have proposed and studied three algorithms for estimating heart rate. The first algorithm is based on applying FFT on an FIR filtered signal. In the second algorithm, autocorrelation was performed on the filtered data. Thirdly, we used a peak finding algorithm in conjunction with a moving average preceded by a clipper to determine the heart rate. The results obtained were compared with the heart rate readings from a pulse oximeter. With a mean difference of 2.6 bpm, the heart rate from Doppler radar matched that from the pulse oximeter most frequently when the peak finding algorithm was used. The results obtained using autocorrelation and peak finding algorithm (with standard deviations of 2.6 bpm and 4.0 bpm) suggest that a single channel Doppler radar system can be a viable alternative to contact heart rate monitors in patients for whom contact measurements are not feasible.Keywords
Funding Information
- National Science Foundation (IIP-1831303,CNS-2039089)
- University of Hawaii
This publication has 12 references indexed in Scilit:
- Fast heart rate extraction using CW Doppler radar with interpolated discrete Fourier transform algorithmAIP Advances, 2020
- High-Accuracy Real-Time Monitoring of Heart Rate Variability Using 24 GHz Continuous-Wave Doppler RadarIEEE Access, 2019
- Accurate tunable-Q wavelet transform based method for QRS complex detectionComputers and Electrical Engineering, 2019
- Accurate Heart Rate Detection from On-Body Continuous Wave Radar Sensors Using Wavelet Transform2018
- Contact-Free Monitoring of Human Vital Signs via a Microwave Sensor2011
- Assessment of Heart Rate Variability and Respiratory Sinus Arrhythmia via Doppler RadarIEEE Transactions on Microwave Theory and Techniques, 2009
- Non-invasive respiratory movement detection and monitoring of hidden humans using ultra wideband pulse radar2004
- Range Correlation and$ I/ Q$Performance Benefits in Single-Chip Silicon Doppler Radars for Noncontact Cardiopulmonary MonitoringIEEE Transactions on Microwave Theory and Techniques, 2004
- A digital signal processor for Doppler radar sensing of vital signsIEEE Engineering in Medicine and Biology Magazine, 2002
- Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrierIEEE Transactions on Biomedical Engineering, 2000