A 10-GHz frequency-domain fluorometer
Authors:
- 1 September 1990
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 61 (9) , 2331-2337
Abstract
We describe the design and performance of a 10-GHz harmonic-content frequency-domain fluorometer. The modulated excitation is provided by the harmonic content of a train of ps pulses. High-speed and/or high-frequency detection was attained with a triode-type microchannel plate photomultiplier tube (MCP PMT) from Hamamatsu, R-2566-6, with 6 μm channels. To minimize the cost of the electronic components, and to minimize the noise due to these components, the detection circuits consists of two frequency ranges, 10 MHz–2 GHz and 2–10 GHz. The upper frequency limit of 10 GHz is determined by the current MCP PMT, so the usual configuration includes a low-noise 2–10-GHz amplifier. This amplifier is easily replaced with a 2–18-GHz amplifier to allow operation to 18 GHz and the use of faster PMTs, should they become available in the future. Measurement of known optical delays demonstrates the accuracy of the instrument. For instance, a 1.69 ps optical delay was measured as 1.7±0.4 ps from 0.5 to 10 GHz, and 1.7±0.2 ps from 2 to 8 GHz, where the uncertainty indicates the maximum deviation from the expected value. The data were shown to be free of systematic errors by measurements on fluorophores with single exponential decays, with decay times ranging from 61 ps to 1.24 ns. Measurement of anisotropy decays with correlation times of 24 ps are shown and it is predicted that correlation times as short as 1 ps could be measured with this instrument. And finally, the sensitivity of the instrumentation was demonstrated by measurements of the very weak intrinsic tryptophan emission of deoxyhemoglobin, which displays decay times ranging from 2 to 820 ps.Keywords
This publication has 33 references indexed in Scilit:
- Fluorescence studies of the conformational dynamics of parvalbumin in solution: lifetime and rotational motions of the single tryptophan residueBiochemistry, 1989
- Distance distributions in proteins recovered by using frequency-domain fluorometry. Applications to troponin I and its complex with troponin CBiochemistry, 1988
- Fluorescence lifetime distributions of 1,6-diphenyl-1,3,5-hexatriene in phospholipid vesiclesBiochemistry, 1987
- Transient effects in fluorescence quenching measured by 2-GHz frequency-domain fluorometryThe Journal of Physical Chemistry, 1987
- Resolution of complex anisotropy decays by variable frequency phase-modulation fluorometry: a stimulation studyBiochimica et Biophysica Acta (BBA) - Protein Structure and Molecular Enzymology, 1986
- Picosecond phase fluorometry and color delay errorOptics Communications, 1983
- Fluorescence depolarization of tryptophan residues in proteins: a molecular dynamics studyBiochemistry, 1983
- Picosecond phase fluorometry by mode-locked cw lasersOptics Communications, 1982
- Initial fluorescence depolarization of tyrosines in proteinsJournal of the American Chemical Society, 1982
- Mode-Locked Lasers: Measurements of Very Fast Radiative Decay in Fluorescent SystemsScience, 1969