Abstract
This paper presents the results of an experimental investigation undertaken to evaluate different purging solutions to enhance the removal of multiple heavy metals, particularly chromium, nickel, and cadmium, from a low buffering clay, specifically kaolin, during electrokinetic remediation. Experiments were conducted on kaolin spiked with Cr(VI), Ni(II), and Cd(II) in concentrations of 1,000, 500, and 250 mg/kg, respectively, which simulate typical electroplating waste contamination. A total of five different tests were performed to investigate the effect of different electrode purging solutions on the electrokinetic remedial efficiency. A constant DC voltage gradient of 1 V/cm was applied for all the tests. The removal of heavy metals from the soil using tap water as the purging solution was very low. When 1 M acetic acid was used as the purging solution in the cathode, the removal of chromium, nickel, and cadmium was increased to 20, 19, and 13%, respectively. Using 0.1 M ethylene diamine tetraacetic ac...

This publication has 23 references indexed in Scilit: