Biomechanical Comparison of Four Different Fixation Techniques for Pediatric Tibial Eminence Avulsion Fractures
Authors:
- Andrew T. MaharAMAndrew T. Mahar
- Doug DuncanDDDoug Duncan
- Richard OkaRORichard Oka
- Alexandra LowryALAlexandra Lowry
- Bruce GillinghamBGBruce Gillingham
- Henry ChambersHCHenry Chambers
- 1 March 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 28 (2) , 159-162
Abstract
Several different methods have been used to repair tibial eminence avulsion fractures. It is not clear which is the best stabilization method. The purpose of this study was to compare the biomechanical stability of tibial eminence avulsion fractures using suture, resorbable screw, resorbable nail, and metal screw techniques. Sixteen immature bovine knees were dissected leaving just the anterior cruciate ligament. A fracture was created using a curved osteotome, The knees were randomly stabilized with either 2 single-armed #2 Ethibond sutures, 3 bioabsorbable nails, a single resorbable screw, or a single metal screw. Femurs were tested with the knee flexed to 35 degrees to simulate anterior tibial translation. Tests involved loading between 5 N and 150 N for 200 cycles, then a tensile failure test at 0.5 mm/sec. Cyclic fragment deformation, initial fragment stiffness, and failure load were compared using a 1-way analysis of variance (p < 0.05). There were no significant mechanical differences across groups. The variability in performance was much greater for both the suture and resorbable screw repairs. Both sutures and resorbable screw constructs resulted in a deformation that was 1 mm greater than that of the resorbable nails or a metal screw. Increased fracture separation for sutures and resorbable screw groups indicates a potential loss in reduction during cyclic, physiologic loads. Each group could withstand up to 85 lb of tensile force before failure, but it is unlikely that this force would occur with incidental loads during the early rehabilitation period. There was not a clear biomechanical advantage to performing any particular fixation method in this study. This suggests that the surgeon can use their clinical judgment and experience to determine the fixation technique.Keywords
This publication has 13 references indexed in Scilit:
- A Biomechanical Comparison of Repair Techniques for Anterior Cruciate Ligament Tibial Avulsion Fracture Under Cyclic LoadingArthroscopy, 2005
- Suture Versus Screw Fixation of Displaced Tibial Eminence Fractures: A Biomechanical ComparisonArthroscopy, 2005
- Arthroscopic fixation of avulsion fractures of the tibial eminence: technique and outcomeArthroscopy, 2004
- Therapeutic outcome of hypropic anisometropic amblyopia in jichi Medical SchoolJAPANESE ORTHOPTIC JOURNAL, 2003
- Hamstring graft tibial fixation: biomechanical properties of different linkage systemsKnee Surgery, Sports Traumatology, Arthroscopy, 2002
- Comparative Pull-Out and Cyclic-Loading Strength Tests of Anchorage of Hamstring Tendon Grafts in Anterior Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 1999
- Initial Fixation Strength of Modified Patellar Tendon Grafts for Anatomic Fixation in Anterior Cruciate Ligament ReconstructionArthroscopy, 1999
- Arthroscopic suture fixation of displaced tibial eminence fracturesArthroscopy, 1994
- Fracture of the tibial spine in adults and children. A review of 31 casesThe Journal of Bone and Joint Surgery. British volume, 1992
- A fracture of the intercondylar eminence of the tibia treated by arthroscopic fixationArthroscopy, 1991