Finger Joint Stiffness Estimation with Joint Modular Soft Actuators for Hand Telerehabilitation
Open Access
Abstract
In a telerehabilitation environment, it is difficult for a therapist to understand the condition of a patient’s finger joints because of the lack of direct assessment. In particular, not enabling the provision of spasticity evaluation significantly reduces the optimal performance of telerehabilitation. In a previous study, it has been proposed that finger stiffness could be estimated using an analytical model of a whole-finger soft actuator. However, because the whole-finger soft actuators require high air pressure for high bending performance and are costly to customize for each patient, using joint modular soft actuators for telerehabilitation turns to be a necessity, though stiffness estimation with joint modular soft actuators has not been studied yet. Another problem is caused by using a marker-based joint angle measurement, which requires the markers to be attached to the exact positions, and limits its application in telerehabilitation. In this study, we proposed a procedure of finger joint stiffness estimation that combines information acquired from a joint modular soft actuator and a marker-less hand joint position acquisition device. Correction parameters were added to the previous analytical model for -the bending analysis of a joint assisted using a joint modular soft actuator. Moreover, a multi-variate regression model was implemented for correcting joint angles obtained from the hand joint position acquisition device. As a result, a reasonable accuracy of stiffness estimation was achieved for rehabilitation with the joint modular soft actuators, which suggests the possibility of using the proposed method to evaluate the finger spasticity in a telerehabilitation environment. This is a big step forward towards optimal hand telerehabilitation.Keywords
Funding Information
- Grant-in-Aid for Scientific Research (B), JSPS KAKENHI (22H03450)
This publication has 38 references indexed in Scilit:
- An Analysis of the Precision and Reliability of the Leap Motion Sensor and Its Suitability for Static and Dynamic TrackingSensors, 2014
- Movement therapy induced neural reorganization and motor recovery in stroke: A reviewJournal of Bodywork and Movement Therapies, 2011
- Design of a 2-Finger Hand Exoskeleton for Finger Stiffness MeasurementsApplied Bionics and Biomechanics, 2009
- Spastic movement disorder: impaired reflex function and altered muscle mechanicsThe Lancet Neurology, 2007
- Weakness Is the Primary Contributor to Finger Impairment in Chronic StrokeArchives of Physical Medicine and Rehabilitation, 2006
- Characterization of Pb(Zr,Ti)O3 thin films deposited on stainless steel substrates by RF-magnetron sputtering for MEMS applicationsSensors and Actuators A: Physical, 2006
- Proximal Interphalangeal Joint Stiffness: Measurement and AnalysisThe Journal of Hand Surgery, 2005
- Probability of Regaining Dexterity in the Flaccid Upper LimbStroke, 2003
- A Study of Inter-rater Reliability of the Modified Ashworth Scale (MAS) in Spasticity in Patients with Stroke.Rihabiriteishon igaku, 2002
- Characterization of multijoint finger stiffness: dependence on finger posture and force directionIEEE Transactions on Biomedical Engineering, 1998