Kinetic analysis of cardiac troponin I release is no more accurate than a single 24-h measurement in predicting in-hospital outcome after cardiac surgery
Authors:
- J.-L. FellahiJFJ.-L. Fellahi
- J.-L. HanouzJHJ.-L. Hanouz
- X. GuéXGX. Gué
- E. MonierEME. Monier
- L. GuillouLGL. Guillou
- B. RiouBRB. Riou
- 1 June 2008
- journal article
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 25 (6) , 490-497
Abstract
Background and objective A single cardiac troponin I (cTnI) 24-h measurement is an independent predictor of short- and long-term adverse outcome after coronary surgery. We compared a single cTnI 24-h measurement and kinetic analysis of cTnI release in predicting in-hospital outcome in unselected cardiac surgery patients. Methods Consecutive patients (n = 184) undergoing cardiac surgery with cardiopulmonary bypass were included and divided into two groups according to the time course of postoperative peak serum cTnI (6 or 24 h after surgery). Serial measurements of cTnI were performed the day before surgery, at the end of surgery and 6, 24 and 120 h after surgery in all patients. The total amount of cTnI released (integrated area under the curve), postoperative major adverse cardiac events (ventricular arrhythmias, myocardial infarction and congestive heart failure) and in-hospital death were recorded. Data are expressed as median (95% CI). Results In all, 152 (83%) patients had an early peak cTnI (6 h after surgery) and 32 (17%) patients had a late peak cTnI (24 h after surgery). The integrated area under the curve differed between both groups: 159 (142–178) vs. 321 (255–590), respectively, P < 0.001. Major adverse cardiac events and/or death (22 vs. 9%, P = 0.04) was greater in patients with a late peak cTnI. The integrated area under the curve and the peak value of cTnI were no more accurate than a single 24-h measurement in predicting the occurrence of major adverse cardiac events and/or death. Conclusions Kinetic analysis of cTnI release was no more accurate than a single 24-h measurement in predicting in-hospital poor outcome.Keywords
This publication has 24 references indexed in Scilit:
- Determination of the threshold of cardiac troponin I associated with an adverse postoperative outcome after cardiac surgery: a comparative study between coronary artery bypass graft, valve surgery, and combined cardiac surgeryCritical Care, 2007
- Early and Delayed Myocardial Infarction after Abdominal Aortic SurgeryAnesthesiology, 2005
- Case Definitions for Acute Coronary Heart Disease in Epidemiology and Clinical Research StudiesCirculation, 2003
- Cardiac Troponin I Is an Independent Predictor of In-hospital Death after Adult Cardiac SurgeryAnesthesiology, 2002
- Utility of cardiac troponin measurement after cardiac surgeryClinica Chimica Acta, 2001
- It’s Time for a Change to a Troponin StandardCirculation, 2000
- Troponin levels in patients with myocardial infarction after coronary artery bypass graftingThe Annals of Thoracic Surgery, 2000
- Pericardial Cardiac Troponin I Release After Coronary Artery Bypass GraftingAnesthesia & Analgesia, 1999
- Cardiac troponin I in diagnosis of perioperative myocardial infarction after cardiac surgeryJournal of Cardiothoracic and Vascular Anesthesia, 1998
- Use of cardiac troponin I as a marker of perioperative myocardial ischemiaThe Annals of Thoracic Surgery, 1995