Comparing laboratory and field samples of lime–cement-improved Norwegian clay
Authors:
- 1 December 2022
- journal article
- research article
- Published by Emerald Publishing in Géotechnique Letters
- Vol. 12 (4) , 265-271
Abstract
Improvement of the structural integrity of clay-rich soil is crucial to mitigate risks related to ground movements, and representative procedures are needed to quantitatively describe the reproducibility and authenticity of laboratory-mixed (LM) clay model specimens. Here, two standardised industry protocols for preparation of laboratory lime–cement (LC) improved clay samples are compared with field LC-improved clay. Samples from both dry deep-mixed (DDM) clay columns and LM clay, with different binder quantities, were tested for density, water content and unconfined compressive strength, and analysed by X-ray micro-computed tomography. The results showed clear differences in sample density and ‘macro-porosity’ described as entrapped air resulting from field installation and laboratory preparation. For the field samples, the macro-porosity was relatively low, indicating that the air used in the binder injection is successfully evacuated along the drilling rod as sought after during DDM works. For the laboratory samples, prepared with two standard moulding preparation protocols, the macro-porosity was larger and have an influence on the measured strength and stiffness of the improved soil. An inverse relation between the mechanical strength under unconfined compression and porosity was found. In conclusion, the industry-standard laboratory moulding techniques fail to reproduce specimens that are representative for field conditions.Keywords
This publication has 12 references indexed in Scilit:
- Real Time 3D Observations of Portland Cement Carbonation at CO2 Storage ConditionsEnvironmental Science & Technology, 2020
- Microstructural Analyses of a Stabilized Sand by a Deep-Mixing MethodJournal of Geotechnical and Geoenvironmental Engineering, 2020
- Looking for the Signal: A guide to iterative noise and artefact removal in X-ray tomographic reconstructions of porous geomaterialsAdvances in Water Resources, 2017
- Multi-scale laboratory evaluation of the physical, mechanical, and microstructural properties of soft highway subgrade soil stabilized with calcium carbide residueCanadian Geotechnical Journal, 2016
- Applicability of molding procedures in laboratory mix tests for quality control and assurance of the deep mixing methodSoils and Foundations, 2015
- High-resolution X-ray computed tomography in geosciences: A review of the current technology and applicationsEarth-Science Reviews, 2013
- The Deep Mixing Method2013
- Consolidation stress effects on the strength of stabilised Swedish soilsProceedings of the Institution of Civil Engineers - Ground Improvement, 2006
- Uniformity of lime-cement columns for deep mixing: a field studyProceedings of the Institution of Civil Engineers - Ground Improvement, 2005
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984