Impact of a nickel-reduced stainless steel implant on striated muscle microcirculation: A comparativein vivo study
Authors:
- 13 August 2001
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 57 (3) , 404-412
Abstract
The impairment of skeletal muscle microcirculation by a biomaterial may have profound consequences. With moderately good physical and corrosion characteristics, implant-quality stainless steel is particularly popular in orthopedic surgery. However, due to the presence of a considerable amount of nickel in the alloy, concern has been voiced in respect to local tissue responses. More recently a stainless steel alloy with a significant reduction of nickel has become commercially available. We, therefore, studied in vivo nutritive perfusion and leukocytic response of striated muscle to this nickel-reduced alloy, and compared these results with those of the materials conventional stainless steel and titanium. Using the hamster dorsal skinfold chamber preparation and intravital microscopy, we could demonstrate that reduction of the nickel quantity in a stainless steel implant has a positive effect on local microvascular parameters. Although the implantation of a conventional stainless steel sample led to a distinct and persistent activation of leukocytes combined with disruption of the microvascular endothelial integrity, marked leukocyte extravasation, and considerable venular dilation, animals with a nickel-reduced stainless steel implant showed only a moderate increase of these parameters, with a clear tendency of recuperation. Titanium implants merely caused a transient increase of leukocyte-endothelial cell interaction within the first 120 min, and no significant change in macromolecular leakage, leukocyte extravasation, or venular diameter. Pending biomechanical and corrosion testing, nickel-reduced stainless steel may be a viable alternative to conventional implant-quality stainless steel for biomedical applications. Concerning tolerance by the local vascular system, titanium currently remains unsurpassed. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res 57: 404–412, 2001Keywords
This publication has 26 references indexed in Scilit:
- Quantification of Video‐Taped Images in Microcirculation Research Using Inexpensive Imaging Software (Adobe Photoshop)Microcirculation, 2000
- Striated muscle microvascular response to silver implants: A comparativein vivo study with titanium and stainless steelJournal of Biomedical Materials Research, 2000
- Toxicity measurement of orthopedic implant alloy degradation products using a bioluminescent bacterial assayJournal of Biomedical Materials Research, 1999
- Evaluation of nickel toxicity on liver, spleen, and kidney of mice after administration of high-dose metal ionJournal of Biomedical Materials Research, 1998
- Biocompatibility testing of NiTi screws using immunohistochemistry on sections containing metallic implantsJournal of Biomedical Materials Research, 1996
- Cobalt and Chromium Concentrations in Patients With Metal on Metal Total Hip ReplacementsClinical Orthopaedics and Related Research, 1996
- Evaluation of carcinogenicity and chronic toxicity associated with orthopedic implants in miceJournal of Biomedical Materials Research, 1994
- Scope and perspectives of intravital microscopy - bridge over from in vitro to in vivoImmunology Today, 1993
- Does corrosion matter?The Journal of Bone and Joint Surgery. British volume, 1988
- Technical report—a new chamber technique for microvascular studies in unanesthetized hamstersZeitschrift für Die Gesamte Experimentelle Medizin, 1980