Coronary Artery Calcification Scoring in Low-Dose Ungated CT Screening for Lung Cancer: Interscan Agreement
- 1 May 2010
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 194 (5) , 1244-1249
Abstract
OBJECTIVE. In previous studies detection of coronary artery calcification (CAC) with low-dose ungated MDCT performed for lung cancer screening has been compared with detection with cardiac CT. We evaluated the interscan agreement of CAC scores from two consecutive low-dose ungated MDCT examinations.SUBJECTS AND METHODS. The subjects were 584 participants in the screening segment of a lung cancer screening trial who underwent two low-dose ungated MDCT examinations within 4 months (mean, 3.1 ± 0.6 months) of a baseline CT examination. Agatston score, volume score, and calcium mass score were measured by two observers. Interscan agreement of stratification of participants into four Agatston score risk categories (0, 1–100, 101–400, > 400) was assessed with kappa values. Interscan variability and 95% repeatability limits were calculated for all three calcium measures and compared by repeated measures analysis of variance.RESULTS. An Agatston score > 0 was detected in 443 baseline CT examinations (75.8%). Inte...Keywords
This publication has 35 references indexed in Scilit:
- Coronary Calcium Screening Using Low-Dose Lung Cancer Screening: Effectiveness of MDCT with Retrospective ReconstructionAmerican Journal of Roentgenology, 2008
- Coronary Arterial Calcification on Low-Dose Ungated MDCT for Lung Cancer Screening: Concordance Study with Dedicated Cardiac CTAmerican Journal of Roentgenology, 2008
- ACCF/AHA 2007 Clinical Expert Consensus Document on Coronary Artery Calcium Scoring By Computed Tomography in Global Cardiovascular Risk Assessment and in Evaluation of Patients With Chest PainJACC, 2007
- Variability of Repeated Coronary Artery Calcium Measurements on Low-Dose ECG-Gated 16-MDCTAmerican Journal of Roentgenology, 2006
- The impact of motion artifacts on the reproducibility of repeated coronary artery calcium measurementsEuropean Radiology, 2006
- Coronary Artery Calcium Measurement with Multi–Detector Row CT and Low Radiation Dose: Comparison between 55 and 165 mAsRadiology, 2005
- Age and gender distribution of coronary artery calcium measured by four-slice computed tomography in 2,030 persons with no symptoms of coronary artery diseaseThe American Journal of Cardiology, 2002
- Small lesions in the heart identified at electron beam CT: calcification or noise?Radiology, 1994
- Detection of heart calcification with electron beam CT: interobserver and intraobserver reliability for scoring quantification.Radiology, 1994
- Quantification of coronary artery calcification using ultrafast computed tomographyCoronary Artery Disease, 1993