Factors Associated with Failure of Surface‐Modified Implants up to Four Years of Function
Authors:
- 1 June 2012
- journal article
- research article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 14 (3) , 347-358
Abstract
Objectives: The relative impact of innovative treatment concepts on the failure of surface‐modified implants is not well understood. This retrospective study aimed to explore this using data obtained in a university postgraduate training center.Material and Methods: Patients treated with implants for a variety of indications over a 3‐year period were included. All implants had been at least 1 year in function. Clinical records were evaluated for implant failure and in reference to implant length/diameter/location, time from tooth loss to implant placement, bone condition (native/grafted), surgical protocol (two‐/one‐stage), loading protocol (delayed/early/immediate), type of prosthesis (removable/fixed), surgeon's experience level (resident/trainee) and specialty (periodontist/oral surgeon). The impact of each covariate on failure was tested using the Fisher's exact test. Kaplan‐Meier survival functions were constructed and Mantel‐Cox log–rank tests were used to compare survival functions. To correct for possible interaction, Cox proportional Hazards regression was adopted.Results: Forty‐one of 1,180 (3.5%) implants were lost in 34/461 (7.4%) patients (245 ♀, 216 ♂; mean age 51, range 18–90). Factors showing significant impact on failure on the basis of univariate analyses were implant location (p = .015), surgical protocol (p = .002), loading protocol (p = .002), surgeon's experience level (p = .035) and specialty (p = .001). When controlling for other covariates, only the loading protocol had a significant influence (p = .049) with early loading more prone to failure (p = .014) when compared with delayed loading. Immediate loading and delayed loading showed comparable implant survival (p = .311).Conclusions: Implant therapy may be highly successful in a training center where inexperienced clinicians are strictly monitored and personally guided. Implant specific variables do not affect implant survival but early loading is a risk indicator for implant failure, whereas immediate loading is not.Keywords
This publication has 69 references indexed in Scilit:
- A Retrospective Analysis of Early and Delayed Loading of Full‐Arch Mandibular Prostheses Using Three Different Implant Systems: Clinical Results with Up to 5 Years of LoadingClinical Implant Dentistry and Related Research, 2009
- Implant Treatment of Patients with Edentulous Jaws: A 20‐Year Follow‐UpClinical Implant Dentistry and Related Research, 2008
- Early loading of ITI implants supporting maxillary fixed full‐arch prosthesesClinical Oral Implants Research, 2008
- Immediate functional loading of TiOblast dental implants in full‐arch edentulous mandibles: a 3‐year prospective studyClinical Oral Implants Research, 2008
- Five‐Year Clinical Evaluation of Short Dental Implants Placed in Posterior Areas: A Retrospective StudyJournal of Periodontology, 2008
- Impact of local and systemic factors on the incidence of failures up to abutment connection with modified surface oral implantsJournal of Clinical Periodontology, 2007
- Early loading of sandblasted and acid‐etched implants: a randomized‐controlled double‐blind split‐mouth study. Five‐year resultsClinical Oral Implants Research, 2007
- Impact of local and systemic factors on the incidence of oral implant failures, up to abutment connectionJournal of Clinical Periodontology, 2007
- Immediate Loading of Brånemark System Implants®: A Comparison Between TiUniteTM and Turned Implants Placed in the Anterior MandibleClinical Implant Dentistry and Related Research, 2006
- Stability measurements of one-stage Brånemark implants during healing in mandiblesInternational Journal of Oral and Maxillofacial Surgery, 1999