Sirolimus coating on heparinized stents prevents restenosis and thrombosis
Authors:
- 24 April 2017
- journal article
- research article
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 31 (10) , 1337-1345
Abstract
The aim of this study was to evaluate the inhibitory effect of sirolimus coating on the occurrence of restenosis and thrombosis with heparinized stents. Heparin and dopamine were conjugated by chemical bonding and anchored on the stent surface by a mussel-inspired adhesion mechanism. Subsequently, sirolimus was coated with poly lactic-glycolic acid on the heparinized stent surface. The heparin was well attached to the surface, and the surface was smooth after sirolimus coating. The smoothness of the surface was maintained after expansion of the stent. The amount of sirolimus released from the stent was 67.3% ± 4.55% within 7 days, followed by continual release up to day 28. The proliferation of smooth muscle cells was successfully arrested (51.3% ± 2.25% at 7 days of culture) by sirolimus released from the stent. Platelet adhesion was clearly prevented in the heparin-coated group (78.0 ± 8.00/1.8 cm2) compared to that in the heparin noncoated group (5.0 ± 1.00/1.8 cm2). Animal studies showed that the heparin and sirolimus-coated stent group had no obvious inflammatory response and no change in the fibrin score compared to those in the other groups. However, restenosis clearly decreased in the heparin and sirolimus-coated group (12.3% ± 3.54%) compared to the bare-metal stent group (27.5% ± 8.52%) and the heparin-coated group (25.3% ± 11.79%). These results suggest that heparinized surface-based sirolimus coating may be a useful approach for the prevention of restenosis and stent thrombosis.Keywords
Funding Information
- Korean Health Technology R&D Project Ministry of Health & Welfare, Republic of Korea (HI13C1527)
- Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT & Future Planning (2014R1A1A1005948)
This publication has 31 references indexed in Scilit:
- Enhancement of Blood Compatibility of Poly(urethane) Substrates by Mussel-Inspired Adhesive Heparin CoatingBioconjugate Chemistry, 2011
- Paclitaxel/sirolimus combination coated drug-eluting stent: In vitro and in vivo drug release studiesJournal of Pharmaceutical and Biomedical Analysis, 2011
- Collagen/heparin coating on titanium surface improves the biocompatibility of titanium applied as a blood‐contacting biomaterialJournal of Biomedical Materials Research Part A, 2010
- Drug-Eluting Stents in Preclinical StudiesCirculation: Cardiovascular Interventions, 2008
- Mussel-Inspired Surface Chemistry for Multifunctional CoatingsScience, 2007
- Late Thrombosis a Concern with Drug‐Eluting StentsJournal of Interventional Cardiology, 2007
- Arsenic trioxide eluting stent reduces neointima formation in a rabbit iliac artery injury modelCardiovascular Research, 2006
- Technology Insight: an overview of research in drug-eluting stentsNature Clinical Practice Cardiovascular Medicine, 2005
- Cellular Heterogeneity of the Vascular Tunica MediaArteriosclerosis, Thrombosis, and Vascular Biology, 1997
- Rapamycin (AY-22,989), a new antifungal antibiotic. I. Taxonomy of the producing streptomycete and isolation of the active principle.The Journal of Antibiotics, 1975