Wearable Wireless-Enabled Oscillometric Sphygmomanometer: A Flexible Ambulatory Tool for Blood Pressure Estimation
- 25 September 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (6) , 1287-1298
Abstract
This article presents the design of an unobstrusive and wireless-enabled blood pressure (BP) monitoring system that is suitable for ambulatory use. By adopting low-profile electromechanical actuators and a compact printed circuit board design, this lightweight device can be worn directly on the occlusive cuff, therefore eliminating the need of two separate entities and long tubing interconnect usually seen in traditional ambulatory BP monitors (ABPM). Instead of executing the BP estimation algorithm directly on the device, the proposed design rather sends the raw oscillometric signal through a Bluetooth Low Energy link, thus granting any Bluetooth-enabled device to gather and process the signal using a dedicated application. This in turn allows to assess several systolic & diastolic BP estimation algorithms found in the literature without being limited by the device ressources. Three of them were tested with the designed prototype and validated with a reference equipment on 11 subjects. Overall, two of the algorithms revealed a mean absolute difference with the reference equipment of less than 5 mmHg and almost zero bias along with a standard deviation of less than 6 mmHg. Reproducibility results shown a mean difference between successive measurements of less than 3.1 mmHg and a standard deviation of less than 2.4 mmHg. The assembled prototype dimensions are 63.8 mm (W) x 134.8 mm (L) x 24.8 mm (H) and features an autonomy of 63.1 hours. Comparison with commercial ABPM devices shown that the proposed design is 18% to 33% smaller volume-wise and height is reduced by 17% to 25%.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
- SMAART
- Canada Research Chair in Smart Biomedical Microsystems
This publication has 23 references indexed in Scilit:
- Thresholds for Diagnosing Hypertension Based on Automated Office Blood Pressure Measurements and Cardiovascular RiskHypertension, 2015
- Oscillometric Blood Pressure Estimation: Past, Present, and FutureIEEE Reviews in Biomedical Engineering, 2015
- Oscillometric measurement of systolic and diastolic blood pressures validated in a physiologic mathematical modelBioMedical Engineering OnLine, 2012
- Principles and Techniques of Blood Pressure MeasurementCardiology Clinics, 2010
- Extracting oscillometric pulses from the cuff pressure: does it affect the pressures determined by oscillometric blood pressure monitors?Blood Pressure Monitoring, 2006
- Recommendations for Blood Pressure Measurement in Humans and Experimental AnimalsCirculation, 2005
- Update on Methods & Simulators for Evaluation of Noninvasive Blood Pressure MonitorsJournal of Clinical Engineering, 1994
- Characterization of the oscillometric method for measuring indirect blood pressureAnnals of Biomedical Engineering, 1982
- The Meaning of the Point of Maximum Oscillations in Cuff Pressure in the Indirect Measurement of Blood Pressure—Part IIJournal of Biomechanical Engineering, 1980
- A Comparison of Direct and Indirect Blood-Pressure DeterminationsCirculation, 1953