High-Accuracy, Wide-Dynamic Range Continuous FBG Interrogator Based on an AWG
- 21 March 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Abstract
Although arrayed waveguide gratings (AWGs) are widely used in fiber Bragg grating (FBG) demodulation systems, their applications in real environments have been limited due to their narrow dynamic range and inability to continuously demodulate FBGs because of the finite bandwidth of AWG channels. Here, we developed a wide-dynamic-range, high-accuracy, continuous-demodulation FBG interrogator utilizing a dual-input channel on-chip silicon AWG. The introduction of two input channels in the AWG allowed two spectral peaks in each channel; therefore, staggered spectral peaks were realized. A joint-peak demodulation algorithm based on this spectrum is proposed to improve the dynamic range and demodulation accuracy. With the proposed structure and algorithm, we achieved continuous interrogation with a demodulation accuracy of 25.58 pm and a dynamic range of 24.5 nm in the 1537.5-1565.3 nm wavelength region. The relative demodulation accuracy within the full range reaches 0.1%. The dynamic range of adjacent channels is 5.4 nm, which is approximately 4 times greater than the dynamic range of an FBG conventional demodulation system using an AWG, and the relative demodulation accuracy is 0.47%. This developed interrogator, with a core size of 420 μm × 300 μm, theoretically explained and experimentally verified the possibility of the accurate measurement of an arbitrary FBG wavelength with high demodulation accuracy in the measurement range. This work achieved continuous monitoring of external temperature by FBGs and demonstrated their significant potential in expanding the application field of FBGs.Keywords
Funding Information
- National Key Research and Development Program of China (2022YFB3205300)
- National Natural Science Foundation of China (52375548)
- Basic research program of Jiangsu (BK20240452)
- China Postdoctoral Science Foundation (2024M762581)
- Fundamental Research Funds for the Central Universities (xzy012024047)
This publication has 30 references indexed in Scilit:
- On-Chip Sub-Picometer Continuous Wavelength Fiber-Bragg-Grating InterrogatorPhotonic Sensors, 2024
- SOI-based 15-channel arrayed waveguide grating design for fiber Bragg grating interrogatorPhotonics and Nanostructures - Fundamentals and Applications, 2023
- Flexible temperature sensor with high sensitivity ranging from liquid nitrogen temperature to 1200 °CInternational Journal of Extreme Manufacturing, 2022
- Design and fabrication of AWG with large bandwidth applied in FBG interrogation systemOptics & Laser Technology, 2022
- SOI-based arrayed waveguide grating with extended dynamic range for fiber Bragg grating interrogatorOptical Fiber Technology, 2022
- Photonic integrated field-programmable disk array signal processorNature Communications, 2020
- Narrowband interrogation of plasmonic optical fiber biosensors based on spectral combsOptics & Laser Technology, 2017
- Preliminary Investigation of an SOI-based Arrayed Waveguide Grating Demodulation Integration MicrosystemScientific Reports, 2014
- Design considerations for a fibre Bragg grating interrogation system utilizing an arrayed waveguide grating for dynamic strain measurementMeasurement Science and Technology, 2013
- Interrogation of fibre Bragg grating sensors using an arrayed waveguide gratingMeasurement Science and Technology, 2005