Experimental Study of the Effects of Torsional Loading on Three Types of Nickel-Titanium Endodontic Instruments
Authors:
- Andreea-Simona Boscornea-PușcuABAndreea-Simona Boscornea-Pușcu
- Laura OrelLOLaura Orel
- Oana-Alexandra Velea-BartaOVOana-Alexandra Velea-Barta
- Razvan Mihai HorhatRHRazvan Mihai Horhat
- Meda-Lavinia NegruțiuMeda-Lavinia Negruțiu
- Luminița Maria NicaLNLuminița Maria Nica
- Virgil-Florin DumaVirgil-Florin Duma
- Dan Ioan StoiaDan Ioan Stoia
- Carmen OprișCOCarmen Opriș
- Cosmin SinescuCosmin Sinescu
Open Access
- 5 August 2021
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 11 (16) , 7224
Abstract
In modern endodontics, nickel-titanium (NiTi) rotary instruments are used on a large scale for root canal shaping. Nevertheless, the separation of an instrument is a serious concern during shaping. The aim of this study is to determine and compare the torsional fracture characteristics of three types of NiTi endodontic instruments, each with different cross-section designs and movements performed during root canal shaping: Endostar E3 (Endostar, Poldent Co. Ltd., Warsaw, Poland); Reciproc R25 (VDW, Munich, Germany); and Protaper Next X2 (Dentsply Maillefer, Ballaigues, Switzerland). Fifteen instruments are used in this study, divided in three groups (n = 5): Group Endostar, Group Reciproc and Group Protaper. For testing, each instrument is used to shape five simulated root canals, following which its torsional stress to failure is measured. The fracture lengths of all three groups are roughly between 2 and 3 mm from the tip. Higher values of the moment of torsion in fracture, and smaller values of the maximum twisting angle are observed for Group Endostar, as well as closer to circular cross-sections. However, the values of the shear tension are similar for all three groups, because the disadvantage given by the fracture section shape for Groups Reciproc and Protaper is compensated either by size or by intrinsic properties of the instrument material. For the shear tension the Endostar values are insignificantly increased (Kruskal–Wallis test, p = 0.207), and in the case of the maximum twist angle the Protaper values are insignificantly increased (Kruskal–Wallis test, p = 0.287). Because of the instruments shape and conicity, the analysis had to be carried out separately with regard to the length of the fractured tip. Rules-of-thumb are extracted from the study for current practice: if a blockage of the first 2 to 3 mm part of the tip can be anticipated (by the excessive curving of the instrument), the handpiece must be adjusted to torque values that do not exceed 1.5 to 2.5 N · cm for Endostar and 1 to 2 N · cm for Reciproc and Protaper instruments.Keywords
Funding Information
- Romanian Ministry of Research, Innovation and Digitization (CNCS/CCCDI–UEFISCDI project PN-III-P2-2.1-PED-2020-4423)
This publication has 56 references indexed in Scilit:
- Evaluation of Forces Generated on Three Different Rotary File Systems in Apical Third of Root Canal using Finite Element AnalysisJournal of Clinical and Diagnostic Research, 2014
- Centering Ability and Influence of Experience When Using WaveOne Single-File Technique in Simulated CanalsInternational Journal of Dentistry, 2012
- Cyclic fatigue resistance of two reciprocating nickel–titanium instruments after immersion in sodium hypochloriteInternational Endodontic Journal, 2012
- Relationship between flexibility and physical, chemical, and geometric characteristics of rotary nickel-titanium instrumentsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2010
- Cyclic fatigue of NiTi rotary instruments in a simulated apical abrupt curvatureInternational Endodontic Journal, 2010
- Influence of cyclic torsional loading on the fatigue resistance of K3 instrumentsInternational Endodontic Journal, 2008
- Dimensional characterization and mechanical behaviour of K3 rotary instrumentsInternational Endodontic Journal, 2008
- Canal preparation using only one Ni‐Ti rotary instrument: preliminary observationsInternational Endodontic Journal, 2007
- Instrument fracture: mechanisms, removal of fragments, and clinical outcomesEndodontic Topics, 2007
- Influence of simulated clinical use on the torsional behavior of nickel-titanium rotary endodontic instrumentsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2006