Potential for Change in US Diagnosis of Hip Dysplasia Solely Caused by Changes in Probe Orientation: Patterns of Alpha-angle Variation Revealed by Using Three-dimensional US
Authors:
- Myles MabeeMMMyles Mabee
- Vimarsha G. SwamiVSVimarsha G. Swami
- Lucy JamiesonLJLucy Jamieson
- Kelvin ChowKCKelvin Chow
- Richard B. ThompsonRTRichard B. Thompson
- 1 December 2014
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 273 (3) , 870-878
Abstract
To use three-dimensional ( 3D three-dimensional ) ultrasonography (US) to quantify the alpha-angle variability due to changing probe orientation during two-dimensional ( 2D two-dimensional ) US of the infant hip and its effect on the diagnostic classification of developmental dysplasia of the hip ( DDH developmental dysplasia of the hip ). In this institutional research ethics board-approved prospective study, with parental written informed consent, 13-MHz 3D three-dimensional US was added to initial 2D two-dimensional US for 56 hips in 35 infants (mean age, 41.7 days; range, 4-112 days), 26 of whom were female (mean age, 38.7 days; range, 6-112 days) and nine of whom were male (mean age, 50.2 days; range, 4-111 days). Findings in 20 hips were normal at the initial visit and were initially inconclusive but normalized spontaneously at follow-up in 23 hips; 13 hips were treated for dysplasia. With the computer algorithm, 3D three-dimensional US data were resectioned in planes tilted in 5° increments away from a central plane, as if slowly rotating a 2D two-dimensional US probe, until resulting images no longer met Graf quality criteria. On each acceptable 2D two-dimensional image, two observers measured alpha angles, and descriptive statistics, including mean, standard deviation, and limits of agreement, were computed. Acceptable 2D two-dimensional images were produced over a range of probe orientations averaging 24° (maximum, 45°) from the central plane. Over this range, alpha-angle variation was 19° (upper limit of agreement), leading to alteration of the diagnostic category of hip dysplasia in 54% of hips scanned. Use of 3D three-dimensional US showed that alpha angles measured at routine 2D two-dimensional US of the hip can vary substantially between 2D two-dimensional scans solely because of changes in probe positioning. Not only could normal hips appear dysplastic, but dysplastic hips also could have normal alpha angles. Three-dimensional US can display the full acetabular shape, which might improve DDH developmental dysplasia of the hip assessment accuracy.Keywords
This publication has 12 references indexed in Scilit:
- Hip sonography update. Quality-management, catastrophes – tips and tricksMedical Ultrasonography, 2013
- Cochrane Review: Screening programmes for developmental dysplasia of the hip in newborn infantsEvidence-Based Child Health: A Cochrane Review Journal, 2013
- Developmental dysplasia of the hipThe Lancet, 2007
- Ultrasound Measurements in the Management of Unstable Hips Treated With the Pavlik HarnessJournal of Pediatric Orthopaedics, 2006
- Comparable ultrasound measurements of ten anatomical specimens of infant hip joints by the methods of graf and terjesenActa Radiologica, 2004
- The natural history of developmental dysplasia of the hip after early supervised treatment in the Pavlik harness. A prospective, longitudinal follow-up.The Journal of Bone and Joint Surgery. British volume, 2002
- Three-dimensional sonographic evaluation of developmental dysplasia of the hip: preliminary findings.Radiology, 1994
- Ultrasound of the infant hip. Part 2. Validity of the methodPediatric Radiology, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Fundamentals of Sonographic Diagnosis of Infant Hip DysplasiaJournal of Pediatric Orthopaedics, 1984