Low Sensitivity of Admission Lung US Compared to Chest CT for Diagnosis of Lung Involvement in a Cohort of 82 Patients with COVID-19 Pneumonia
Authors:
- Carla Maria Irene QuaratoCarla Maria Irene Quarato
- Antonio MirijelloAntonio Mirijello
- Donato LacedoniaDLDonato Lacedonia
- Raffaele RussoRRRaffaele Russo
- Michele Maria MaggiMMMichele Maria Maggi
- Gaetano ReaGRGaetano Rea
- Annalisa SimeoneASAnnalisa Simeone
- Cristina BorelliCBCristina Borelli
- Beatrice FeragalliBFBeatrice Feragalli
- Giulia SciosciaGSGiulia Scioscia
- Maria Pia Foschino BarbaroMBMaria Pia Foschino Barbaro
- Valentina MassaVMValentina Massa
Open Access
Abstract
Background and Objectives: The potential role of lung ultrasound (LUS) in characterizing lung involvement in Coronavirus disease 2019 (COVID-19) is still debated. The aim of the study was to estimate sensitivity of admission LUS for the detection of SARS-CoV-2 lung involvement using Chest-CT (Computed Tomography) as reference standard in order to assess LUS usefulness in ruling out COVID-19 pneumonia in the Emergency Department (ED). Methods: Eighty-two patients with confirmed COVID-19 and signs of lung involvement on Chest-CT were consecutively admitted to our hospital and recruited in the study. Chest-CT and LUS examination were concurrently performed within the first 6–12h from admission. Sensitivity of LUS was calculated using CT findings as a reference standard. Results: Global LUS sensitivity in detecting COVID-19 pulmonary lesions was 52%. LUS sensitivity ranged from 8% in case of focal and sporadic ground-glass opacities (mild disease), to 52% for a crazy-paving pattern (moderate disease) and up to 100% in case of extensive subpleural consolidations (severe disease), although LUS was not always able to detect all the consolidations assessed at Chest-CT. LUS sensitivity was higher in detecting a typical Chest-CT pattern (60%) and abnormalities showing a middle-lower zone predominance (79%). Conclusions: As admission LUS may result falsely negative in most cases, it should not be considered as a reliable imaging tool in ruling out COVID-19 pneumonia in patients presenting in ED. It may at least represent an expanded clinical evaluation that needs integration with other diagnostic tests (e.g., nasopharyngeal swab, Chest-CT).Keywords
This publication has 38 references indexed in Scilit:
- Sensitivity of Chest CT for COVID-19: Comparison to RT-PCRRadiology, 2020
- CT Imaging of the 2019 Novel Coronavirus (2019-nCoV) PneumoniaRadiology, 2020
- 0.9% saline versus Plasma-Lyte as initial fluid in children with diabetic ketoacidosis (SPinK trial): a double-blind randomized controlled trialCritical Care, 2020
- Ultrasound Diagnosis of Ventilator-Associated PneumoniaChest, 2016
- Ultrasound signs of pulmonary fibrosis in systemic sclerosis as timely indicators for chest computed tomographyScandinavian Journal of Rheumatology, 2015
- Transthoracic ultrasound in the assessment of pleural and pulmonary diseases: use and limitationsLa radiologia medica, 2014
- Assessment of ultrasound acoustic artifacts in patients with acute dyspnea: a multicenter studyActa Radiologica, 2012
- New sonographic techniques for harmonic imaging—Underlying physical principlesEuropean Journal of Radiology, 2007
- Ultrasonography of Pleura and LungUltraschall in der Medizin - European Journal of Ultrasound, 2003
- AAPM/RSNA Physics Tutorial for Residents: Topics in USRadioGraphics, 2003