Effect of Cooling Methods on CFRP–Concrete Bond Behavior After High-Temperature Exposure: An Experimental Study
Open Access
Abstract
Concrete structures are highly vulnerable to fire exposure, which accelerates the degradation of mechanical properties and may lead to partial or total structural failure. Externally bonded carbon fiber-reinforced polymer (CFRP) systems are widely used for post-fire strengthening; however, the bond behavior at the interfaces between CFRP and fire-damaged concrete, particularly under different cooling conditions, is not yet fully understood. In this study, the bond behavior was investigated experimentally and theoretically. Double-lap joint tests of thirty-nine specimens were conducted, including three unheated control specimens and thirty-six specimens exposed to temperatures of 200 °C, 400 °C, and 600 °C for durations of one and two hours. Two cooling methods, natural air cooling and water cooling, were applied prior to CFRP bonding. The results indicated that bond strength increased under exposure conditions of no more than 400 °C, whereas a significant reduction was observed at 600 °C. Water cooling resulted in lower bond strength compared with air cooling, while longer exposure durations improved bond performance under certain thermal conditions. The reasons behind the phenomena were analyzed in detail. Based on the experimental results, an analytical model for predicting the bond strength at the interfaces between fire-damaged concrete and CFRP sheets was developed. The model can account for the effects of peak temperatures, exposure durations, and cooling methods, and demonstrated high predictive accuracy (R2 = 0.94). The findings provide valuable insight into CFRP–concrete interaction after fire exposure and offer practical guidance for the assessment and rehabilitation of fire-damaged concrete structures.Keywords
Funding Information
- Qinchuangyuan Scientists-Engineers Teams of Shaanxi Province (2025QCY-KXJ-137)
This publication has 61 references indexed in Scilit:
- The flexural response of RC beams strengthened by EB/NSM techniques using FRP and metal materials: a state-of-the-art reviewInnovative Infrastructure Solutions, 2023
- Bond-slip behavior between fiber reinforced concrete and CFRP compositesAin Shams Engineering Journal, 2019
- Technical and Administrative Assessment of Plasco Building IncidentInternational Journal of Civil Engineering, 2018
- Tests on the Steel–Concrete Bond Strength in Steel Reinforced Concrete (SRC) Columns After Fire ExposureFire Technology, 2016
- Collapse simulation of reinforced concrete high‐rise building induced by extreme earthquakesEarthquake Engineering & Structural Dynamics, 2012
- Effect of bond degradation on fire resistance of FRP-strengthened reinforced concrete beamsComposites Part B: Engineering, 2011
- Revealing the temperature history in concrete after fire exposure by microscopic analysisCement and Concrete Research, 2009
- Compressive strength–color change relation in mortars at high temperatureCement and Concrete Research, 2004
- Concrete at high temperature with application to tunnel fireComputational Mechanics, 2002
- Effect of fire on concrete and concrete structuresProgress in Structural Engineering and Materials, 2000