Diagnostic accuracy of the 1,3-β-D-glucan test for pneumocystis pneumonia in a tertiary university hospital in Denmark: A retrospective study
- 11 December 2018
- journal article
- research article
- Published by Oxford University Press (OUP) in Medical Mycology
- Vol. 57 (6) , 710-717
Abstract
1,3-β-D-glucan (BG), a cell-wall component of most fungi including Pneumocystis (PC), is recommended by international guidelines for screening for pneumocystis pneumonia (PCP) in hematologic patients. We retrospectively validated the BG test in our tertiary university hospital. Forty-five patients (median age 53 years, 33% female) tested for PC by polymerase chain reaction (PCR) and/or immunoflourescence (IF)-microscopy with a stored blood sample within ±5 days of the PC test were tested by the Fungitell (cutoff 80 pg/ml). Cases had symptoms and radiology compatible with PCP and positive IF-microscopy (proven PCP, n = 8) or positive PCR (probable PCP, n = 10). Controls had no compatible symptoms/radiology and negative tests for PC on conventional testing (no PCP, n = 24), or positive PCR/IF-microscopy (colonized, n = 3). Median BG-levels were 1108 pg/ml (proven PCP), 612 pg/ml (probable PCP), 29 pg/ml (colonized), and 48 pg/ml (controls, P < 0.001). Compared to the PCP case/control classification, the BG test showed sensitivities of 83–89% and specificities of 64–74%, positive likelihood ratio (LR) of 3.2 and negative LR of 0.23 at recommended cutoff and moderate agreement between tests. Optimal cutoff was ≥73 pg/ml. In PCR-positive cases, the agreement between the BG test and IF-microscopy was 78–89% with fair/moderate agreement. Elevated BG levels were seen in controls with probable invasive fungal infections (n = 4), hemodialysis, bacterial infections and/or betalactams. To conclude, 11% of patients with PCP would be missed if the BG test had been used for diagnosing PCP. Specificity was moderate. Among PCR-positive patients, the BG test identified more cases than IF-microscopy. BG testing is potentially helpful but sensitivity is insufficient to exclude PCP.Keywords
This publication has 29 references indexed in Scilit:
- Evaluation of PCR in Bronchoalveolar Lavage Fluid for Diagnosis of Pneumocystis jirovecii Pneumonia: A Bivariate Meta-Analysis and Systematic ReviewPLOS ONE, 2013
- Pneumocystis Pneumonia in Solid Organ TransplantationAmerican Journal of Transplantation, 2013
- Accuracy of β -D-glucan for the diagnosis of Pneumocystis jirovecii pneumonia: a meta-analysisClinical Microbiology and Infection, 2013
- Quantitative real-time PCR and the (1 → 3)-β-d-glucan assay for differentiation between Pneumocystis jirovecii pneumonia and colonizationClinical Microbiology and Infection, 2012
- Association Between Circulating DNA, Serum (1->3)- -D-Glucan, and Pulmonary Fungal Burden in Pneumocystis PneumoniaClinical Infectious Diseases, 2012
- Diagnostic Accuracy of Serum 1,3-β- d -Glucan for Pneumocystis jiroveci Pneumonia, Invasive Candidiasis, and Invasive Aspergillosis: Systematic Review and Meta-AnalysisJournal of Clinical Microbiology, 2012
- Quantitative PCR to diagnosePneumocystispneumonia in immunocompromised non-HIV patientsEuropean Respiratory Journal, 2011
- Serum (1→3)-β- d -Glucan Levels in Primary Infection and Pulmonary Colonization with Pneumocystis jiroveciiJournal of Clinical Microbiology, 2011
- -D-Glucan Assay for the Diagnosis of Invasive Fungal Infections: A Meta-analysisClinical Infectious Diseases, 2011
- Serum markers in interstitial pneumonia with and without Pneumocystis jiroveciicolonization: a prospective studyBMC Infectious Diseases, 2009