Environmental and Biological Monitoring of Platinum-Containing Drugs in Two Hospital Pharmacies Using Positive Air Pressure Isolators
Open Access
- 22 October 2012
- journal article
- research article
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 57 (3) , 374-383
Abstract
Environmental and biological monitoring of platinum containing drugs was implemented in two French hospital pharmacies using positive air pressure isolators and having similar working procedures when preparing antineoplastic drugs. Wipe sampling of surfaces, gloves, and vials was performed in the preparation room and in storage areas. All employees involved in the preparation of antineoplastic drugs were tested for urinary platinum on Monday before work and Friday after shift. Only traces of platinum were detected on surfaces in the preparation room outside the isolators (less than 1.61 pg cm−2). However, in one center, significant contamination was found in the storage area of the drug vials, which can most likely be linked to the rupture of a platinum vial and due to inefficient cleaning procedures. Surfaces inside the isolators were found to be contaminated (maximum: 198.4 pg cm−2). A higher level of contamination was detected in one pharmacy and could be explained by the lack of overgloving with regular changes during the preparation process. Nitrile gloves used during drug handling outside the isolator showed the highest platinum concentration (maximum: 5.86ng per pair). With regards to platinum urine concentration, no significant difference was found between exposed and unexposed pharmacy personnel. Isolator technology combined with individual protective measures seems to be efficient to protect workers from occupational exposure to antineoplastic drugs, whereas specific individual protective procedures implemented were focussing on the risk of handling vials outside the isolator (e.g. high frequency of glove changing). Moreover, overgloving inside the isolator would contribute to substantially decrease inner surface contamination and should be recommended in order to limit the transfer of chemical contamination to the end products.Keywords
This publication has 39 references indexed in Scilit:
- The PhaSeal® system: Impact of its use on workplace contamination and duration of chemotherapy preparationJournal of Oncology Pharmacy Practice, 2011
- Evaluation of Antineoplastic Drug Exposure of Health Care Workers at Three University-Based US Cancer CentersJournal of Occupational and Environmental Medicine, 2010
- Évaluation du risque génotoxique chez les infirmiers manipulant les cytostatiquesAnnales de biologie clinique, 2010
- Program to monitor surface contamination by methotrexate in a hematology–oncology satellite pharmacyAmerican Journal of Health-System Pharmacy, 2007
- Environmental Contamination with Cytotoxic Drugs in Healthcare Using Positive Air Pressure IsolatorsAnnals of Occupational Hygiene, 2005
- Dermal exposure to cyclophosphamide in hospitals during preparation, nursing and cleaning activitiesInternational Archives of Occupational and Environmental Health, 2005
- Surface contamination of chemotherapy drug vials and evaluation of new vial-cleaning techniques: Results of three studiesAmerican Journal of Health-System Pharmacy, 2005
- Occupational Dermal Exposure to Cyclophosphamide in Dutch Hospitals: A Pilot StudyAnnals of Occupational Hygiene, 2004
- External contamination of vials containing cytotoxic agents supplied by pharmaceutical manufacturersJournal of Oncology Pharmacy Practice, 2003
- Implementing a multiple‐isolator unit for centralized preparation of cytotoxic drugs in a cancer center pharmacyInternational Journal of Clinical Pharmacy, 1999