High-Speed Gas Chromatography Using Synchronized Dual-Valve Injection
Authors:
- 19 May 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (13) , 3517-3524
Abstract
A novel injection technique for high-speed gas chromatography is demonstrated. Synchronized dual-valve injection is shown to provide peak widths as low as 1.5 ms (width at half-height) for an unretained analyte. This was achieved using a 0.5-m DB-5 column with an internal diameter of 100 μm and a film thickness of 0.4 μm operated at a temperature of 150 °C with a column absolute head pressure of 85 psi, resulting in a dead time of only to = 26 ms (∼1900 cm/s, 26 mL/min). Using the DB-5 column in a 1-m length under the same instrumental parameters, with a resulting linear flow velocity of 935 cm/s (12.7 mL/min, to = 117 ms), a minimum peak width of 3.3 ms was obtained. During an isothermal separation, 10 analytes were separated in a time window of 400 ms. A rigorous comparison of experimental and theoretical band-broadening data based on the Golay equation showed that band broadening is limited almost entirely by the chromatographic band broadening terms expressed by the Golay equation and not by extra column band broadening due to the injection process. Synchronized dual-valve injection offers a rugged and inexpensive design, providing extremely reproducible injections with peak height precision of 2.4% (RSD) and low run-to-run variation in retention times, with an average standard deviation less than 0.1 ms. Herein, synchronized dual-valve injection is demonstrated as a proof of principle using high-speed diaphragm valves. It is foreseen that the injection technique could be readily implemented using a combination of thermal modulation and high-speed valve hardware, thus optimizing the mass transfer and not significantly sacrificing the limit of detection performance for high-speed GC. Further implications are that, if properly implemented, high-speed temperature programming coupled with this new technology should lead to very large peak capacities for ∼1-s separations.Keywords
This publication has 17 references indexed in Scilit:
- Evaluation of time-of-flight mass spectrometric detection for fast gas chromatographyJournal of Chromatography A, 2000
- Comprehensive Two-Dimensional High-Speed Gas Chromatography with Chemometric AnalysisAnalytical Chemistry, 1998
- Stepper Motor Controlled Micro Gas Valve Inlet System for Gas ChromatographyAnalytical Chemistry, 1998
- New horizons in gas chromatography: Field applications of microminiaturized gas chromatographic techniquesTrAC Trends in Analytical Chemistry, 1994
- Cryofocusing inlet with reverse flow sample collection for gas chromatographyAnalytical Chemistry, 1993
- Instrumentation and strategies for high-speed gas chromatographyThe Analyst, 1991
- Sample enrichment in high speed narrow bore capillary gas chromatographyJournal of High Resolution Chromatography, 1988
- Theoretical aspects and practical potentials of rapid gas analysis in capillary gas chromatographyAnalytical Chemistry, 1987
- Influence of instrumental contributions on the apparent column efficiency in high speed gas chromatographyAnalytical Chemistry, 1978
- CORROSION ACTIVITY IN 1965—PART IIndustrial & Engineering Chemistry, 1966