Measurement of fetal automated fractional shortening using two-dimensional tracking in multiple centers
- 11 January 2021
- journal article
- research article
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 48 (1) , 83-90
Abstract
Purpose To establish a normal reference range for automated fractional shortening (Auto FS) in normal singleton fetuses measured at multiple centers. Methods This study was conducted from May 2017 to March 2019. It was undertaken on normal singleton fetuses. First, a four-chamber view of the fetal heart was recorded in the B-mode. Then, the region of interest was set on the edge of the ventricular septum and on the edge of the ventricular muscle at a point one-third away from the atrioventricular valve and toward the cardiac apex. Tracking was automatically performed. Values measured in the right ventricle were defined as R-Auto FS, and in the left ventricle as L-Auto FS. Furthermore, combined-Auto FS was defined as the measurement across both ventricles. Results A total of 442 normal fetuses were assessed. R-Auto FS decreased significantly with gestational age, and L-Auto FS showed a similar tendency (Spearman’s correlation analysis: rs = − 0.415 and rs = − 0.252, respectively). Combined-Auto FS showed a similar decline as the gestational age increased (rs = − 0.451). Conclusion In this study, we succeeded in defining a reference Auto FS value not only at one institution but also multiple centers. This study suggests that Auto FS can be used clinically and effectively.Keywords
Funding Information
- Japan Society for the Promotion of Science (JP16K11114,19K09788)
This publication has 11 references indexed in Scilit:
- Twenty‐four Segment Transverse Ventricular Fractional Shortening: A New Technique to Evaluate Fetal Cardiac FunctionJournal of Ultrasound in Medicine, 2017
- Assessment of diastolic function of normal fetal heart using dual‐gate DopplerUltrasound in Obstetrics & Gynecology, 2017
- Computing the Z Score and Centiles for Cross‐sectional Analysis: A Practical ApproachJournal of Ultrasound in Medicine, 2017
- Fetal cardiac dimensions at 14–40 weeks' gestation obtained using cardio‐STIC‐MUltrasound in Obstetrics & Gynecology, 2011
- Guidelines for the Evaluation of Heart Failure in the Fetus With or Without HydropsPediatric Cardiology, 2004
- Intracardiac pressures in the human fetusHeart, 2000
- How to construct ‘normal ranges’ for fetal variablesUltrasound in Obstetrics & Gynecology, 1998
- Role of the Pulmonary Circulation in the Distribution of Human Fetal Cardiac Output During the Second Half of PregnancyCirculation, 1996
- Fetal echocardiographyAmerican Journal of Obstetrics and Gynecology, 1984
- Quantitative assessment of growth and function of the cardiac chambers in the normal human fetus: a prospective longitudinal echocardiographic study.Circulation, 1984