Abstract
In this paper, the authors propose a mechanically flexible direct conversion x-ray detector as a potential solution for portable and conformal digital x-ray imaging. It consists of a micropillar structured layer of 100-μm-thick amorphous selenium (a-Se) on a flexible thin film transistor (TFT) backplane with a pixel size of 70 μm as a substrate. The flexible substrate is made of an optically transparent polyimide with a heat resistance of more than 200 °C. It is bonded on a glass carrier for rigid substrate handling during the amorphous silicon (a-Si) TFT process. Separating the flexible substrate from the glass carrier is partly facilitated by a debonding layer sandwiched between them. A two-dimensional electrical simulation analysis revealed a possible charge generation and collection mechanism within the micropillared a-Se layer. An x-ray image captured by the curved flexible detector indicated that a pillarlike a-Se conversion layer can be used to perform x-ray imaging. This is, to the best of our knowledge, the first demonstration of a flexible digital x-ray direct conversion detector.Keywords
This publication has 15 references indexed in Scilit:
- Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image SensorsSensors, 2011
- Amorphous selenium and its alloys from early xeroradiography to high resolution X‐ray image detectors and ultrasensitive imaging tubesPhysica Status Solidi (b), 2009
- Solid-state, flat-panel, digital radiography detectors and their physical imaging characteristicsClinical Radiology, 2008
- Limited cone-beam CT and intraoral radiography for the diagnosis of periapical pathologyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2007
- Status and prospects of digital detector technology for CR and DRRadiation Protection Dosimetry, 2005
- Using a flat-panel detector in high resolution cone beam CT for dental imagingDentomaxillofacial Radiology, 2004
- Direct-conversion flat-panel X-ray image sensors for digital radiographyProceedings of the IEEE, 2002
- X-ray sensitivity of photoconductors: application to stabilized a-SeJournal of Physics D: Applied Physics, 2000
- X-ray detectors for digital radiographyPhysics in Medicine & Biology, 1997
- Improvement of charge transport in SeAs glasses by doping with halogensJournal of Non-Crystalline Solids, 1994