Marginal soft tissue stability around conical abutments inserted with the one abutment‐one time protocol after 5 years of prosthetic loading
- 11 October 2018
- journal article
- research article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 20 (6) , 976-982
Abstract
Background: Soft tissue stability is crucial to obtain and maintain optimal esthetic results.Purpose: This study aimed to investigate, over 5 years, the soft tissue response using a conical abutment together with the “one‐abutment one‐time” (OA‐OT) protocol in the restoration of implants inserted in the anterior esthetic area.Material and Methods: From January 2011 to January 2012, all consecutive patients requiring an implant n the maxillary area between canines were enrolled. After submerged healing and osseointegration, a definitive abutment with a provisional crown was inserted. After 1 month, the definitive crown was delivered (Tdef). Analog impressions were taken before tooth extraction (T0), at implant insertion Timpl, and Tdef, and at 12 months (T1) and 60 months (T5). Casts were scanned and superimposed using a dedicated software. Differences in vertical height of soft tissue margins between the digitized model casts were calculated and paired sample t test was conducted to compare results. To detect the potential role of biotype, groups (thick vs. thin) were compared by analysis of variance with general linear model.Results: Twenty‐five patients were enrolled. Three patients dropped out. At the 60‐month, 22 patients (12 men and 10 women with mean age of 68.3 ± 11 years) concluded the study follow‐up. Horizontal changes demonstrated gain of 1.06 mm at Timpl, 0.94 mm at Tdef, 0.92 mm at T1 and 0.97 mm at T5 compared to T0. Vertical changes demonstrated gain of 0.84 mm at Timpl, 0.11 mm at Tdef, 0.29 mm at T1 and 0.59 mm at T5 compared to T0. The analysis of variance showed a significant better performance of thick biotype in soft tissue horizontal width (P = .022). No statistical differences were noticed for vertical width (P = .111).Conclusions: The use of a conical abutment together with the OA‐OT approach allowed longitudinal stable soft tissue dimensions.Keywords
This publication has 32 references indexed in Scilit:
- Five‐year cohort prospective study on single implants in the esthetic area restored using one‐abutment/one‐time prosthetic approachClinical Implant Dentistry and Related Research, 2018
- Definitive Abutments Placed at Implant Insertion and Never Removed: Is It an Effective Approach? A Systematic Review and Meta-Analysis of Randomized Controlled TrialsJournal of Oral and Maxillofacial Surgery, 2018
- Platform switch and dental implants: A meta-analysisJournal of Dentistry, 2015
- Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: a systematic reviewInternational Journal of Oral and Maxillofacial Surgery, 2015
- The use of acellular dermal matrix membrane for vertical soft tissue augmentation during submerged implant placement: a case seriesClinical Oral Implants Research, 2014
- Marginal bone and soft tissue behavior following platform switching abutment connection/disconnection– a dog model studyClinical Oral Implants Research, 2014
- Influence of Vertical Soft Tissue Thickness on Crestal Bone Changes Around Implants with Platform Switching: A Comparative Clinical StudyClinical Implant Dentistry and Related Research, 2014
- Soft tissue stability at the facial aspect of gingivally converging abutments in the esthetic zone: A pilot clinical studyThe Journal of Prosthetic Dentistry, 2007
- Cell biology of gingival wound healingPeriodontology 2000, 2000
- The barrier between the keratinized mucosa and the dental implantJournal of Clinical Periodontology, 1999