Effectiveness of a visual noise warning system on noise levels in a surgical ICU
Authors:
- Berta Solà-EnriquezBSBerta Solà-Enriquez
- Andrés M. Vélez-PereiraAndrés M. Vélez-Pereira
- Miriam de NadalMNMiriam de Nadal
- 1 November 2019
- journal article
- research article
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 36 (11) , 857-862
Abstract
The effects of noise are harmful to patients in the ICU environment, and the latter are particularly noisy places. High noise levels seem to be a factor in sleep disturbance, which can, in turn, result in increased morbidity. High noise levels are a recognised problem in ICUs worldwide. The goal was to estimate the effect of a visual noise-warning system on noise levels in a surgical ICU before and after its implementation. A quality improvement initiative. A 12-bedded surgical ICU in a tertiary care university hospital. A total of 148 adult nonintubated and nonsedated patients completed the study, during a 6-week period. Noise levels were continuously recorded using a Type II sound level meter for 6 weeks. The study was divided into three phases. The first 2 weeks, baseline noise levels were measured (phase I). In week 3 of the study, a visual noise warning system (SoundEar II) that changed colour depending on noise levels within the ICU was installed and implemented (phase II). The alarm system was set to light up green at levels below 55 dBA, orange at levels between 55 and 60 dBA and red at levels above 60 dBA. The device was switched off at the beginning of week 5 and the sound level meter continued recording noise levels for another 2 weeks (phase III). Mean night-time noise level was 55.98 dBA in the preintervention phase, 54.14 dB during the intervention, and 54.98 dBA in the postintervention phase. Mean noise level was reduced statistically significantly by 1.35 dBA, and there was a sustained reduction of 0.86 dBA from the baseline noise level 2 weeks after SoundEar II was switched off. Visual noise warning systems can be effective in achieving a reduction in noise levels in critical care units.Keywords
This publication has 26 references indexed in Scilit:
- Sound level intensity severely disrupts sleep in ventilated ICU patients throughout a 24-h period: a preliminary 24-h study of sleep stages and associated sound levelsAnnals of Intensive Care, 2017
- The Efficacy of Earplugs as a Sleep Hygiene Strategy for Reducing Delirium in the ICUCritical Care Medicine, 2016
- Nivel continuo equivalente de ruido en la unidad de cuidado intensivo neonatal asociado al síndrome de burnoutEnfermería Intensiva, 2015
- An investigation of sound levels on intensive care units with reference to the WHO guidelinesCritical Care, 2013
- Mortality associated with short sleep duration: The evidence, the possible mechanisms, and the futureSleep Medicine Reviews, 2010
- Intensive care unit environmentContinuing Education in Anaesthesia Critical Care & Pain, 2009
- Sleep duration and mortality: a systematic review and meta‐analysisJournal of Sleep Research, 2009
- Clinical review: The impact of noise on patients' sleep and the effectiveness of noise reduction strategies in intensive care unitsCritical Care, 2009
- Abnormal Sleep/Wake Cycles and the Effect of Environmental Noise on Sleep Disruption in the Intensive Care UnitAmerican Journal of Respiratory and Critical Care Medicine, 2001
- Adverse Environmental Conditions in the Respiratory and Medical ICU SettingsChest, 1994