In Vitro Verification of Simulated Daily Activities Using Implant-Specific Kinematics from In Vivo Measurements
Open Access
- 2 November 2024
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 11 (11) , 1108
Abstract
The mechanism and boundary conditions used to drive experimental joint simulators have historically adopted standardized profiles developed from healthy, non-total knee arthroplasty (TKA) patients. The purpose of this study was to use implant-specific in vivo knee kinematics to generate physiologically relevant boundary conditions used in the evaluation of cadaveric knees post-TKA. Implant-specific boundary conditions were generated by combining in vivo fluoroscopic kinematics, musculoskeletal modeling-generated quadriceps loading, and telemetric knee compressive loading during activities of daily living (ADL) to dynamically drive a servo-hydraulic knee joint simulator. Ten cadaveric knees were implanted with the same TKA components and mounted in the knee simulator to verify the resulting load profiles against reported fluoroscopic kinematics and loading captured by an ultra-congruent telemetric knee implant. The cadaveric simulations resulted in implant-specific boundary conditions, which accurately recreate the in vivo performance of the like-implanted knee, with Root Mean Square Error (RMSE) in femoral low point kinematics below 2.0 mm across multiple activities of daily living. This study demonstrates the viability of in vivo fluoroscopy as the source of relevant boundary conditions for a novel knee loading apparatus, enabling dynamic cadaveric knee loading that aligns with clinical observations to improve the preclinical development of TKA component design.Keywords
Funding Information
- DePuy Synthes Joint Reconstruction
This publication has 63 references indexed in Scilit:
- Validation of a machine learning technique for segmentation and pose estimation in single plane fluoroscopyJournal of Orthopaedic Research, 2023
- Condylar‐Stabilized TKR May Not Fully Compensate for PCL‐Deficiency: An In Vitro Cadaver StudyJournal of Orthopaedic Research, 2019
- A Probabilistic Approach to Quantify the Impact of Uncertainty Propagation in Musculoskeletal SimulationsAnnals of Biomedical Engineering, 2014
- Comparison of stability and kinematics of the natural knee versus a PS TKA with a ‘third condyle’Knee Surgery, Sports Traumatology, Arthroscopy, 2014
- Relative contributions of design, alignment, and loading variability in knee replacement mechanicsJournal of Orthopaedic Research, 2012
- HiL simulation for testing joint stability after total knee arthroplastyMultibody System Dynamics, 2012
- Posterior stabilized TKA reduce patellofemoral contact pressure compared with cruciate retaining TKA in vitroKnee Surgery, Sports Traumatology, Arthroscopy, 2009
- Three-dimensional kinematics of the human knee during walkingJournal of Biomechanics, 1992
- Entwicklung eines KniegelenksimulatorsArchives of orthopaedic and trauma surgery, 1977
- The mechanics of the knee joint in relation to normal walkingJournal of Biomechanics, 1970