A semi‐adaptive control approach to closed‐loop medication infusion
- 30 May 2016
- journal article
- research article
- Published by Wiley in International Journal of Adaptive Control and Signal Processing
- Vol. 31 (2) , 240-254
Abstract
Summary: This paper presents a semi‐adaptive control approach to closed‐loop medication infusion problems. The rationale underlying this approach is to design a controller that can adapt model parameters with a large impact on the model's fidelity while fixing the remaining parameters at nominal values. In this paper, a control‐oriented model for this purpose is derived via system identification and sensitivity analysis of a low‐order model capturing the direct dose‐response relationship Using the model thus derived, a model‐reference adaptive controller and a composite adaptive controller are designed and compared with each other. In‐silico simulation results using remifentanil's effect on respiratory rate as an example indicate that both controllers can regulate the output at commanded set points. Copyright © 2016 John Wiley & Sons, Ltd.Keywords
Funding Information
- Office of Naval Research (N000141410591)
- Natural Sciences and Engineering Research Council of Canada
- Canadian Institutes of Health Research
This publication has 29 references indexed in Scilit:
- Intraoperative Stroke Volume Optimization Using Stroke Volume, Arterial Pressure, and Heart Rate: Closed-Loop (Learning Intravenous Resuscitator) Versus AnesthesiologistsJournal of Cardiothoracic and Vascular Anesthesia, 2012
- Adaptive computer control of anesthesia in humansComputer Methods in Biomechanics and Biomedical Engineering, 2009
- Advanced Control Strategies for the Regulation of Hypnosis with PropofolIndustrial & Engineering Chemistry Research, 2009
- Norepinephrine weaning in septic shock patients by closed loop control based on fuzzy logicCritical Care, 2008
- Closed-Loop and Decision-Assist Resuscitation of Burn PatientsJournal of Trauma: Injury, Infection & Critical Care, 2008
- Closed-Loop Control of Fluid Therapy for Treatment of HypovolemiaJournal of Trauma: Injury, Infection & Critical Care, 2008
- Adaptive disturbance rejection control for compartmental systems with application to intraoperative anesthesia influenced by hemorrhage and hemodilution effectsInternational Journal of Adaptive Control and Signal Processing, 2008
- Burnout syndrome among critical care healthcare workersCurrent Opinion in Critical Care, 2007
- Spontaneous ventilation with remifentanil in childrenPediatric Anesthesia, 2004
- A new paradigm for the closed-loop intraoperative administration of analgesics in humansIEEE Transactions on Biomedical Engineering, 2002