Treatment of Thoracic Scoliosis
Authors:
- Baron S. LonnerBLBaron S. Lonner
- Joshua D. AuerbachJAJoshua D. Auerbach
- Oheneba Boachie-AdjeiOBOheneba Boachie-Adjei
- Suken A. ShahSSSuken A. Shah
- Naobumu HosoganeNHNaobumu Hosogane
- Peter O. NewtonPNPeter O. Newton
- 1 April 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 34 (8) , 845-851
Abstract
Multicenter retrospective cohort study of 100 consecutive patients. Compare the coronal and sagittal plane radiographic outcomes and clinical rib hump deformity correction in patients who underwent posterior spinal fusion for adolescent idiopathic scoliosis using hybrid instrumentation, polyaxial (POLY) segmental pedicle screw fixation, or monoaxial (MONO) segmental pedicle screw fixation. Instrumentation for the treatment of scoliosis has evolved. Current techniques include use of a combination of hooks, sublaminar wires, and pedicle screws (HYBRID), as well as segmental pedicle screw fixation with either monoaxial or polyaxial screw anchors. Data were obtained from a multicenter prospective database registry. Radiographic assessment was performed from radiographs taken before surgery and 2 years after surgery. Intraoperative parameters assessed included operative time, estimated blood loss, and whether or not a thoracoplasty was performed. Clinical evaluation of the angle of trunk rotation was done with an inclinometer. Preoperative thoracic curvature and curve flexibility, age, Lenke curve type, and number of levels fused was similar for each group. Significantly more anchors per level were used in the MONO group (1.69) and in the HYBRID group (1.24) compared to the POLY group (1.06). There were no statistical differences among the groups with respect to major thoracic curve correction (MONO: 69%; POLY: 68%; HYBRID: 62%, P = 0.22). POLY constructs maintained thoracic kyphosis, whereas MONO and HYBRID had a tendency toward loss of thoracic kyphosis and there was a trend toward a greater percent thoracic angle of trunk rotation correction in the MONO group (55%) compared with the POLY group (32%, P = 0.10), but no differences compared with Hybrid (55%, P > 0.05). Similar coronal and sagittal plane correction was achieved in thoracic adolescent idiopathic scoliosis with 3 different constructs. There was a trend toward improved correction of clinical rib hump deformity with MONO screw constructs compared with POLY screw constructs.Keywords
This publication has 42 references indexed in Scilit:
- Coronal and Sagittal Plane Correction in Adolescent Idiopathic ScoliosisSpine, 2007
- Anterior/Posterior Spinal Instrumentation Versus Posterior Instrumentation Alone for the Treatment of Adolescent Idiopathic Scoliotic Curves More Than 90°Spine, 2006
- Selective Posterior Thoracic Fusions for Adolescent Idiopathic ScoliosisSpine, 2006
- Thoracoscopic Spinal Fusion Compared with Posterior Spinal Fusion for the Treatment of Thoracic Adolescent Idiopathic ScoliosisJournal of Bone and Joint Surgery, 2006
- Comparative Analysis of Pedicle Screw Versus Hybrid Instrumentation in Posterior Spinal Fusion of Adolescent Idiopathic ScoliosisSpine, 2006
- Apical Sublaminar Wires Versus Pedicle Screws—Which Provides Better Results for Surgical Correction of Adolescent Idiopathic Scoliosis?Spine, 2005
- Comparative Analysis of Pedicle Screw Versus Hook Instrumentation in Posterior Spinal Fusion of Adolescent Idiopathic ScoliosisSpine, 2004
- Thoracic scoliosis fusion in adolescent and adult idiopathic scoliosis using posterior translational corrective techniques (Isola): is maximum correction of the thoracic curve detrimental to the unfused lumbar curve?The Spine Journal, 2004
- Correction of Thoracic Adolescent Idiopathic Scoliosis With Segmental Hooks, Rods, and Wisconsin Wires PosteriorlySpine, 2002
- Computer Tomography Evaluation of Cotrel-Dubousset Instrumentation in Idiopathic ScoliosisSpine, 1988