Comparison of Transcranial Doppler and Ultrasound-Tagged Near Infrared Spectroscopy for Measuring Relative Changes in Cerebral Blood Flow in Human Subjects
- 1 February 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 126 (2) , 579-587
Abstract
(TCD) in healthy volunteers during profound hypocapnia and hypercapnia. METHODS: Ten healthy volunteers were monitored with a combination of TCD, UT-NIRS (c-FLOW, Ornim Medical), as well as heart rate, blood pressure, end-tidal Pco2 (PEtco2), end-tidal O2, and inspired O2. Inspired CO2 and minute ventilation were controlled to achieve 5 stable plateau goals of Etco2 at 15–20, 25–30, 35–40, 45–50, and 55–60 mm Hg, for a total of 7 measurements per subject. CBF was assessed at a steady state, with the TCD designated as the reference standard. The primary analysis was a linear mixed-effect model of TCD and UT-NIRS flow with PEtco2, which accounts for repeated measures. Receiver operating characteristic curves were determined for detection of changes in CBF. RESULTS: Hyperventilation (nadir PEtco2 17.1 ± 2.4) resulted in significantly decreased mean flow velocity of the middle cerebral artery from baseline (to 79% ± 22%), but not a consistent decrease in UT-NIRS cerebral flow velocity index (n = 10; 101% ± 6% of baseline). Hypercapnia (peak PEtco2 59.3 ± 3.3) resulted in a significant increase from baseline in both mean flow velocity of the middle cerebral artery (153% ± 25%) and UT-NIRS (119% ± 11%). Comparing slopes versus PEtco2 as a percent of baseline for the TCD (1.7% [1.5%–2%]) and UT-NIRS (0.4% [0.3%–0.5%]) shows that the UT-NIRS slope is significantly flatter, P < .0001. Area under the receiver operating characteristic curve was significantly higher for the TCD than for UT-NIRS, 0.97 (95% confidence interval, 0.92–0.99) versus 0.75 (95% confidence interval, 0.66–0.82). CONCLUSIONS: Our data indicate that UT-NIRS cerebral flow velocity index detects changes in CBF only during hypercarbia but not hypocarbia in healthy subjects and with much less sensitivity than TCD. Additional refinement and validation are needed before widespread clinical utilization of UT-NIRS....Keywords
This publication has 22 references indexed in Scilit:
- Near-infrared spectroscopy as a hemodynamic monitor in critical illnessPediatric Critical Care Medicine, 2011
- Effect of Thrombin Fragment (TP508) on Myocardial Ischemia Reperfusion Injury in a Model of Type 1 Diabetes MellitusCirculation, 2010
- Practice Standards for Transcranial Doppler Ultrasound: Part I—Test PerformanceJournal of Neuroimaging, 2007
- Transcranial Doppler Versus Angiography in Patients With Vasospasm due to a Ruptured Cerebral AneurysmStroke, 2001
- In vivo measurement of cerebral blood flow: a review of methods and applicationsVascular Medicine, 2001
- Cerebral Blood Flow and Metabolic Responses to Sustained Hypercapnia in Awake SheepJournal of Cerebral Blood Flow & Metabolism, 1995
- Dependency of Blood Flow Velocity in the Middle Cerebral Artery on End-Tidal Carbon Dioxide Partial Pressure—A Transcranial Ultrasound Doppler StudyJournal of Cerebral Blood Flow & Metabolism, 1984
- Mechanism and pattern of human cerebrovascular regulation after rapid changes in blood CO2 tension.Journal of Clinical Investigation, 1966
- Human Cerebrovascular Response Time to Elevation of Arterial Carbon Dioxide TensionArchives of Neurology, 1965
- THE EFFECTS OF ALTERED ARTERIAL TENSIONS OF CARBON DIOXIDE AND OXYGEN ON CEREBRAL BLOOD FLOW AND CEREBRAL OXYGEN CONSUMPTION OF NORMAL YOUNG MEN 1Journal of Clinical Investigation, 1948