Active Disturbance Rejection Voltage Control of a Floating Interleaved DC–DC Boost Converter With Switch Fault Consideration
- 18 March 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (12) , 12396-12406
Abstract
To enhance the robustness and to deal with the switch fault uncertainty of floating interleaved dc-dc boost converter (FIBC), an adaptive active disturbance rejection control (ADRC) is proposed in this paper. In particular, the controller parameter b0 is adapted by obtaining approximately the system input control gain b in real time, based on the output duty cycles via digital filters. Compared with the conventional ADRC, the performance of the proposed controller is significantly improved, without the need of extra sensors. Moreover, the influences of the controller parameters on the system dynamical performance are analyzed theoretically, providing a practical guideline for controller tuning. The simulation and experiment results validate the effectiveness and the robustness of the proposed controller.Keywords
Funding Information
- China Scholarship Council (CSC, 201701810139)
This publication has 25 references indexed in Scilit:
- A review on DC/DC converter architectures for power fuel cell applicationsEnergy Conversion and Management, 2015
- Survey on non‐isolated high‐voltage step‐up dc–dc topologies based on the boost converterIET Power Electronics, 2015
- A Survey of Fault Diagnosis and Fault-Tolerant Techniques—Part I: Fault Diagnosis With Model-Based and Signal-Based ApproachesIEEE Transactions on Industrial Electronics, 2015
- Development of a four phase floating interleaved boost converter for photovoltaic systems2014
- Active Disturbance Rejection Control for a Flywheel Energy Storage SystemIEEE Transactions on Industrial Electronics, 2014
- Robust Sliding-Mode Control Design for a Voltage Regulated Quadratic Boost ConverterIEEE Transactions on Power Electronics, 2014
- Fault-tolerant control systems: A comparative study between active and passive approachesAnnual Reviews in Control, 2012
- Analysis, design and experimental results of a floating-output interleaved-input boost-derived DC–DC high-gain transformer-less converterIET Power Electronics, 2011
- Principles of 2-sliding mode designAutomatica, 2007
- A DSP-Based Active Disturbance Rejection Control Design for a 1-kW H-Bridge DC–DC Power ConverterIEEE Transactions on Industrial Electronics, 2005