CT of Metal Implants: Reduction of Artifacts Using an Extended CT Scale Technique
Authors:
- Wilfried BerningWBWilfried Berning
- Steffi ScherfSSSteffi Scherf
- Uwe JoostenUJUwe Joosten
- Alexander JoistAJAlexander Joist
- Klaus EngelkeKEKlaus Engelke
- Heike E. Daldrup-LinkHDHeike E. Daldrup-Link
- 1 January 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 24 (1) , 165-172
Abstract
The purpose of this work was to use an extended CT scale technique (ECTS) to reduce artifacts due to metal implants and to optimize CT imaging parameters for metal implants using an experimental model. Osteotomies were performed in 20 porcine femur specimens. One hundred cobalt-base screws and 24 steel plates were used for osteosynthesis in these specimens. Artificial lesions were produced in 50 screws, such as osteolysis near the screws (mimicking lysis due to infection, tumor, or loosening), displacement of the screws, as well as fractures of the screws. All specimens were examined using eight different CT protocols: four conventional (CCT) and four spiral (SCT) CT protocols with different milliampere-second values (130 and 480 mAs for CCT, 130 and 300 mAs for SCT), kilovolt potentials (120 and 140 kVp), and slice thicknesses (2 and 5 mm). The images were analyzed by three observers using a standard window (maximum window width 4,000 HU) and ECTS (maximum window width 40,000 HU). Receiver operating characteristic analysis was performed, and image quality was assessed according to a five level scale. Metal artifacts were significantly reduced using ECTS (p < 0.05). The highest diagnostic performance was obtained using ECTS with the thinnest slice thickness. Metal artifacts were more pronounced using SCT. In this experimental model, exposure dose and kilovolt potential had no significant impact on diagnostic performance (p > 0.05). ECTS improved imaging of metal implants. In this study, no significant effects of exposure dose and kilovolt potential were noted. Metal artifacts were more prominent using SCT than using CCT.Keywords
This publication has 17 references indexed in Scilit:
- Accuracy of Using Computed Tomography to Identify Pedicle Screw Placement in Cadaveric Human Lumbar SpineSpine, 1997
- Total Hip Prosthesis Metal-Artifact Suppression Using Iterative Deblurring ReconstructionJournal of Computer Assisted Tomography, 1997
- Iterative deblurring for CT metal artifact reductionIEEE Transactions on Medical Imaging, 1996
- Enhanced computed tomographic techniques for the evaluation of total hip arthroplastyThe Journal of Arthroplasty, 1989
- Evaluation of CT Techniques for Reducing Artifacts in the Presence of Metallic Orthopedic ImplantsJournal of Computer Assisted Tomography, 1988
- Reduction of CT artifacts caused by metallic implants.Radiology, 1987
- MR Imaging of Large Nonferromagnetic Metallic Implants at 1.5 TJournal of Computer Assisted Tomography, 1987
- CT BONE DENSITOMETRY OF THE ANCHORAGE OF ARTIFICIAL KNEE JOINTSJournal of Computer Assisted Tomography, 1985
- Basic principles of ROC analysisSeminars in Nuclear Medicine, 1978
- Maximum-likelihood estimation of parameters of signal-detection theory and determination of confidence intervals—Rating-method dataJournal of Mathematical Psychology, 1969