Carotid Ultrasound to Predict Fluid Responsiveness
Authors:
- 21 April 2020
- journal article
- review article
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 39 (10) , 1965-1976
Abstract
Objectives: To perform a systematic review of the accuracy of carotid ultrasound measures in determining volume responsiveness in adults.Methods: We conducted a systematic review of Ovid MEDLINE and Scopus from conception until January 1, 2019. Two independent reviewers used an iterative process to identify relevant articles and abstract information from them. The quality and risk of bias were assessed with the Quality Assessment of Diagnostic Accuracy Studies version 2 tool.Results: We identified 17 relevant articles with 956 patients. The 2 most frequently cited carotid measures of fluid responsiveness were corrected flow time and peak velocity or change in peak velocity with respiration (ΔCDPV). Accordingly, the diagnostic characteristics of corrected flow time in these studies varied widely, with sensitivities from 60% to 73%, specificities from 82% to 92%, and areas under the receiver operating characteristic curves from 0.75 to 0.88. Optimal cutoff values for ΔCDPV ranged from 9.1% to 14%, with areas under the receiver operating characteristic curves from 0.81 to 0.91, sensitivities from 73% to 86%, and specificities from 78% to 86%. Other measures, such as carotid blood flow and carotid diameter, had limited data to support their use. Heterogeneity of the studies prohibited a meta‐analysis. Most studies had a moderate risk of bias and high applicability.Conclusions: Preliminary research suggests that carotid ultrasound measures may be useful adjunct measures of fluid status; however, they should not be interpreted as absolute and should be placed in a clinical context. The most well‐defined and supported measure currently is ΔCDPV, with cutoffs from 9% to 14%. Corrected flow time shows promise, because of heterogeneity of how this value is measured, an optimal cutoff has not been established.Keywords
This publication has 40 references indexed in Scilit:
- Does the Central Venous Pressure Predict Fluid Responsiveness? An Updated Meta-Analysis and a Plea for Some Common Sense*Critical Care Medicine, 2013
- Goal Directed Fluid TherapyCurrent Pharmaceutical Design, 2012
- Prognostic value of B-type natriuretic peptide (BNP) and its potential role in guiding fluid therapy in critically ill septic patientsScandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 2012
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- Diastolic dysfunction and mortality in severe sepsis and septic shockEuropean Heart Journal, 2011
- An Increase in Aortic Blood Flow after an Infusion of 100 ml Colloid over 1 Minute Can Predict Fluid ResponsivenessAnesthesiology, 2011
- Relation between mean arterial pressure and renal function in the early phase of shock: a prospective, explorative cohort studyCritical Care, 2011
- The significance of non-sustained hypotension in emergency department patients with sepsisIntensive Care Medicine, 2009
- Impact of extravascular lung water index on outcomes of severe sepsis patients in a medical intensive care unitRespiratory Medicine, 2008
- Esophageal Doppler Ultrasound Monitor versus Pulmonary Artery Catheter in the Hemodynamic Management of Critically III Surgical PatientsThe Journal of Trauma: Injury, Infection, and Critical Care, 1999