Ventilatory heterogeneity in the normal human lung is unchanged by controlled breathing
- 27 August 2020
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 129 (5) , 1152-1160
Abstract
Measurement of ventilation heterogeneity with the multiple breath N2 washout (MBW) is usually performed using controlled breathing with a fixed tidal volume and breathing frequency. However, it is unclear whether controlled breathing alters the underlying ventilatory heterogeneity. We hypothesized that the width of the specific ventilation distribution (a measure of heterogeneity) would be greater in tests performed during free-breathing compared to those using controlled breathing. Eight normal subjects (age range 23-50 yrs, 5F/3M) twice underwent MRI-based specific ventilation imaging consisting of 5 repeated cycles with the inspired gas switching between 21% and 100% O2 every ~2 minutes (total imaging time ~20 minutes). In each session tests were performed free-breathing (FB, no constraints), and with controlled breathing (CB) at a respiratory rate of 12 breaths/min and no tidal volume control. The specific ventilation distribution in a mid-sagittal slice of the right lung was calculated and the heterogeneity calculated as the full-width at half-max of a gaussian distribution fitted on a log-scale (SV-width). Free-breathing resulted in a range of breathing frequencies from 8.7 to 15.9 bpm (mean 11.5 ± 2.2, P=0.62 compared to CB). Heterogeneity (SV-width) was unchanged by controlled breathing (FB: 0.38 ± 0.12, CB: 0.34 ± 0.09, P=0.18, repeated measures ANOVA). The imposition of a controlled breathing frequency did not significantly affect the heterogeneity of ventilation in the normal lung suggesting that MBW and SVI as typically performed provide an accurate measure of ventilatory heterogeneity.Keywords
Funding Information
- HHS | NIH | National Heart, Lung, and Blood Institute (HL-119263)
- HHS | NIH | National Heart, Lung, and Blood Institute (HL-127980)
- HHS | NIH | National Heart, Lung, and Blood Institute (HL-119201)
- HHS | NIH | National Heart, Lung, and Blood Institute (HL-129990)
This publication has 28 references indexed in Scilit:
- Pendelluft in the bronchial treeJournal of Applied Physiology, 2014
- Validating the distribution of specific ventilation in healthy humans measured using proton MR imagingJournal of Applied Physiology, 2014
- Consensus statement for inert gas washout measurement using multiple- and single- breath testsEuropean Respiratory Journal, 2013
- Relationships between the lung clearance index and conductive and acinar ventilation heterogeneityJournal of Applied Physiology, 2012
- Vertical distribution of specific ventilation in normal supine humans measured by oxygen-enhanced proton MRIJournal of Applied Physiology, 2010
- Oxygen enhanced MR ventilation imaging of the lungMagnetic Resonance Materials in Physics, Biology and Medicine, 1998
- Effect of tidal volume on ventilation maldistributionRespiration Physiology, 1986
- A New Index of the Intrapulmonary Mixture of Inspired AirThorax, 1952
- STUDIES ON INTRAPULMONARY MIXTURE OF GASES. IV. THE SIGNIFICANCE OF THE PULMONARY EMPTYING RATE AND A SIMPLIFIED OPEN CIRCUIT MEASUREMENT OF RESIDUAL AIRJournal of Clinical Investigation, 1941
- STUDIES ON THE INTRAPULMONARY MIXTURE OF GASES. III. AN OPEN CIRCUIT METHOD FOR MEASURING RESIDUAL AIRJournal of Clinical Investigation, 1940