Occupational Radiation Exposure During Intraoperative 3-Dimensional Fluoroscopy in Pelvis and Acetabular Surgery
- 1 November 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 38 (11S) , S29-S34
Abstract
OBJECTIVES: To quantify the occupational radiation exposure with a 3-dimensional (3D) fluoroscopic machine during routine use in pelvic and acetabular surgery and to determine whether the additional radiation exposure encountered with the 3D fluoroscopic spin is within previously accepted limits. METHODS: Design: Prospective cohort study. Setting: Level I trauma center. Patient Selection Criteria: All patients undergoing 3D fluoroscopy intraoperatively during pelvis (OTA/AO 61B,C) or acetabular (OTA/AO 62A-C) surgery between April 2021 and July 2021. Outcome Measures and Comparisons: Radiation dose at standardized locations around the operating room during the spin portion of the 3D fluoroscopy. RESULTS: Seventy-six 3D spins were performed on 69 patients during the study period. The average emitted radiation dose from the machine for the routine fluoroscopy portion of the case was 74.5 mGy. The average displayed radiation dose in the air for the spin portion of the case was 39.9 mGy, an average of 53.6% less radiation than the routine fluoroscopy portion. For the spin portion, the average radiation exposure seen by the patient was 3.42 mGy (centered on the patient) and the average maximal exposure in the room was 0.062 mGy. Minimal radiation was detected outside the operating room doors. CONCLUSIONS: The radiation exposure encountered by operating room personnel with 3D fluoroscopy appears to be within safe occupational limits. The marginal increase in radiation exposure during pelvic and acetabular surgery should not discourage the use of 3D imaging intraoperatively. LEVEL OF EVIDENCE: Level IV, Case Series.Keywords
Funding Information
- AO North America (171408-FEL2020)
This publication has 10 references indexed in Scilit:
- Quantifying Radiation Exposure From Intraoperative Computed Tomography in Traditionally Safe Operating Room ZonesJournal of Orthopaedic Trauma, 2020
- Multidimensional Pelvic Fluoroscopy: A New and Novel Technique for Assessing Safety and Accuracy of Percutaneous Iliosacral Screw FixationJournal of Orthopaedic Trauma, 2020
- Radiation Exposure in OrthopaedicsJBJS Reviews, 2020
- Improved Intraoperative Fluoroscopy for Pelvic and Acetabular SurgeryJournal of Orthopaedic Trauma, 2019
- Radiation Exposure and Health Risks for Orthopaedic SurgeonsJournal of the American Academy of Orthopaedic Surgeons, 2018
- Fracture and Dislocation Classification Compendium—2018Journal of Orthopaedic Trauma, 2018
- Tracking Cumulative Radiation Exposure in Orthopaedic Surgeons and ResidentsJournal of Bone and Joint Surgery, 2017
- Intra-operative multi-dimensional fluoroscopy of guidepin placement prior to iliosacral screw fixation for posterior pelvic ring injuries and sacroiliac dislocation: an early case seriesInternational Orthopaedics, 2017
- Reduction of Radiation Exposure From C-Arm Fluoroscopy During Orthopaedic Trauma Operations With Introduction of Real-Time DosimetryJournal of Orthopaedic Trauma, 2016
- Occupational Radiation Exposure to the SurgeonJournal of the American Academy of Orthopaedic Surgeons, 2005