Development of a C-reactive protein quantification method based on flow rate measurement of an ink solution pushed out by oxygen gas generated by catalase reaction
- 13 December 2023
- journal article
- research article
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (1) , 1-12
Abstract
A novel determination method for protein biomarkers based on on-chip flow rate measurement was developed using a microchip with organic photodiodes (OPDs). This quantitative method is based on the flow rate measurement of an ink solution pushed out by oxygen gas generated through catalase reaction. The amount of oxygen gas generated in the sample reservoir is dependent on the concentration of the analyte; therefore, the flow rate of the ink solution is also dependent on the concentration of the analyte. The concentration of the analyte can thus be estimated by measurement of the ink solution flow rate. The ink solution flow rate was estimated by measuring the migration time of the ink solution between two points using two OPDs placed below the microchannel. The principle of this method was demonstrated by the measurement of catalase using the microchip. In addition, the developed method was applied to the determination of C-reactive protein (CRP), a biomarker of inflammation, based on a catalase-linked immunosorbent assay (C-LISA). The limit of detection for CRP was 0.20 µg/mL. The method was also applied to the determination of CRP in human serum, and the quantitative values obtained by this method were in excellent agreement with those obtained by the conventional enzyme-linked immunosorbent assay (ELISA) method. The developed method does not require a photodetector with high sensitivity and is thus capable of downsizing; therefore, this will be useful for on-site analyses such as point-of-care testing and field measurements. Graphical AbstractKeywords
Funding Information
- Japan Society for the Promotion of Science (22K14709, 21H03578)
- Tokyo Metropolitan Government
This publication has 40 references indexed in Scilit:
- Serum C-Reactive Protein (CRP) as a Simple and Independent Prognostic Factor in Extranodal Natural Killer/T-Cell Lymphoma, Nasal TypePLOS ONE, 2013
- Simple, distance-based measurement for paper analytical devicesLab on a Chip, 2013
- Biosensors for cardiac biomarkers detection: A reviewSensors and Actuators B: Chemical, 2012
- Label-free quantitation of peptide release from neurons in a microfluidic device with mass spectrometry imagingLab on a Chip, 2012
- Multiplexed volumetric bar-chart chip for point-of-care diagnosticsNature Communications, 2012
- An integrated microfluidic system for C-reactive protein measurementBiosensors and Bioelectronics, 2009
- Flow-through functionalized PDMS microfluidic channels with dextran derivative for ELISAsLab on a Chip, 2009
- Miniaturized thermal lens and fluorescence detection system for microchemical chipsJournal of Chromatography A, 2006
- Portable Thermal Lens Spectrometer with Focusing SystemAnalytical Chemistry, 2004
- Systemic inflammatory response predicts survival following curative resection of colorectal cancerBritish Journal of Surgery, 2003