In Vivo Characterization of Titanium Implants Coated with Synthetic Hydroxyapatite by Electrophoresis
Open Access
- 1 April 2005
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Brazilian Dental Journal
- Vol. 16 (1) , 75-81
Abstract
This study compared in vivo the performances of commercially pure titanium (cp Ti) screw dental implants either uncoated or coated with synthetic hydroxyapatite (HA) by electrophoresis. The HA coating was characterized by scanning electron microscopy, energy dispersive spectroscopy (EDS) and Fourier-transform infrared (FT-IR) spectroscopy. Well-adhered carbonated-hydroxyapatite layers (4- to-8-µm-thick) were obtained. In vivo tests were carried out by insertion of both uncoated and HA-coated implants into rabbit tibiae for 8 or 12 weeks. Histomorphometric analysis was performed by scanning electron microscopy with the aid of image-processing software. Results showed significantly greater bone-implant contact for HA-coated implants (p0.05) between both types of implants, although cp Ti had numerically higher percentage of bone content than HA-coated implants. In conclusion, the HA-coated implants had better performance regarding the bone-implant contact area than the uncoated implants; coating by electrophoresis proved to be a valuable process to coat metallic implants with an osteoconductive material such as hydroxyapatite.Keywords
This publication has 11 references indexed in Scilit:
- Dissolution properties of calcium phosphate granules with different compositions in simulated body fluidJournal of Biomedical Materials Research Part A, 2003
- Hydroxyapatite deposition by electrophoresis on titanium sheets with different surface finishingJournal of Biomedical Materials Research, 2002
- Transformation of monetite to hydroxyapatite in bioactive coatings on titaniumSurface and Coatings Technology, 2001
- Bioactive ceramics: the effect of surface reactivity on bone formation and bone cell functionBiomaterials, 1999
- MECHANICAL TESTING OF ELECTROPHORETICALLY DEPOSITED HYDROXYAPATITE1999
- Histomorphometric Analyses of Hydroxyapatite-Coated and Uncoated Titanium Dental Implants in Rabbit Cortical BoneImplant Dentistry, 1999
- Current Status of Ceramic Coatings for Dental ImplantsImplant Dentistry, 1998
- Electrophoretic deposition of hydroxyapatiteJournal of Materials Science: Materials in Medicine, 1997
- Spontaneous Formation of Bonelike Apatite Layer on Chemically Treated Titanium MetalsJournal of the American Ceramic Society, 1996
- Anchorage of TiO2‐blasted, HA‐coated, and machined implants: An experimental study with rabbitsJournal of Biomedical Materials Research, 1995