Monitoring for Compartmental Syndrome Using Near-Infrared Spectroscopy
Authors:
- Larry M. GentilelloLGLarry M. Gentilello
- Peter A. ColePCPeter A. Cole
- Charles N. MockCMCharles N. Mock
- Frederick A. MatsenFMFrederick A. Matsen
- 1 April 1999
- journal article
- research article
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 46 (4) , 613-618
Abstract
The diagnosis of compartmental syndrome (CS) may be delayed because current monitoring techniques are invasive and intermittent and the compartment pressure (CP) that predicts ischemia is variable. Fiber-optic devices using near-infrared (NIR) wavelength reflection can determine the redox state of light-absorbing molecules and have been used to monitor venous hemoglobin saturation to detect ischemia during low-flow states. The purpose of this study was to determine if NIR spectroscopy can provide continuous, transcutaneous, noninvasive monitoring for muscle ischemia in an animal model of CS. Nine swine were anesthetized and a 20-mm NIR probe was placed over the anterolateral compartment of the hind leg to provide continuous determination of muscle oxyhemoglobin level. Needles were inserted into the compartment to measure CP. A nerve stimulator was placed over the peroneal nerve to induce dorsiflexion twitch. Albumin was infused into the muscle to incrementally increase CP until there was complete loss of dorsiflexion, then after 20 minutes fasciotomy was performed. All animals lost dorsiflexion at CP of 43+/-14 mm Hg. There was a significant inverse correlation between CP and oxyhemoglobin level (r = -0.78; p < 0.001) and a correlation between oxyhemoglobin and perfusion pressure (mean arterial pressure minus CP) (r = 0.66; p < 0.001). Redox state was a more consistent predictor of twitch loss than perfusion pressure. Muscle oxyhemoglobin level measured by NIR spectroscopy strongly reflected CP, perfusion pressure, and loss of dorsiflexion twitch. Currently available portable NIR devices may provide the benefit of continuous, noninvasive monitoring for CS. Further studies to determine the role of this technology in the detection of compartmental syndrome are warranted.Keywords
This publication has 15 references indexed in Scilit:
- Intramuscular Deoxygenation during Exercise in Patients Who Have Chronic Anterior Compartment Syndrome of the Leg*Journal of Bone and Joint Surgery, 1997
- Near-infrared spectroscopyCritical Care Medicine, 1997
- THE FUTURECritical Care Clinics, 1996
- Lower Limb Compartment SyndromeThe Journal of Trauma: Injury, Infection, and Critical Care, 1996
- Validation of near-infrared spectroscopy in humansJournal of Applied Physiology, 1994
- Failure of pulse oximetry in the assessment of raised limb intracompartmental pressureInjury, 1994
- Measurement of intracompartmental pressureJournal of Bone and Joint Surgery, 1993
- Near-infrared spectrophotometric monitoring of oxygen distribution to intact brain and skeletal muscle tissuesCritical Care Medicine, 1986
- An Animal Model of the Compartmental SyndromeClinical Orthopaedics and Related Research, 1975
- The deep posterior compartmental syndrome of the legJournal of Bone and Joint Surgery, 1975