Characterization of micro-invasive trabecular bypass stents by ex vivo perfusion and computational flow modeling
Open Access
- 1 March 2014
- journal article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 8, 499-506
Abstract
Micro-invasive glaucoma surgery with the Glaukos iStent® or iStent inject® (Glaukos Corporation, Laguna Hills, CA, USA) is intended to create a bypass through the trabecular meshwork to Schlemm's canal to improve aqueous outflow through the natural physiologic pathway. While the iStent devices have been evaluated in ex vivo anterior segment models, they have not previously been evaluated in whole eye perfusion models nor characterized by computational fluid dynamics. Intraocular pressure (IOP) reduction with the iStent was evaluated in an ex vivo whole human eye perfusion model. Numerical modeling, including computational fluid dynamics, was used to evaluate the flow through the stents over physiologically relevant boundary conditions. In the ex vivo model, a single iStent reduced IOP by 6.0 mmHg from baseline, and addition of a second iStent further lowered IOP by 2.9 mmHg, for a total IOP reduction of 8.9 mmHg. Computational modeling showed that simulated flow through the iStent or iStent inject is smooth and laminar at physiological flow rates. Each stent was computed to have a negligible flow resistance consistent with an expected significant decrease in IOP. The present perfusion results agree with prior clinical and laboratory studies to show that both iStent and iStent inject therapies are potentially titratable, providing clinicians with the opportunity to achieve lower target IOPs by implanting additional stents.Keywords
This publication has 17 references indexed in Scilit:
- Second-generation Trabecular Meshwork Bypass Stent (iStent inject) Increases Outflow Facility in Cultured Human Anterior SegmentsAmerican Journal of Ophthalmology, 2012
- Micro-invasive glaucoma surgeryCurrent Opinion in Ophthalmology, 2012
- Combined iStent trabecular micro-bypass stent implantation and phacoemulsification for coexistent open-angle glaucoma and cataract: a long-term studyBritish Journal of Ophthalmology, 2012
- Randomized Evaluation of the Trabecular Micro-Bypass Stent with Phacoemulsification in Patients with Glaucoma and CataractOphthalmology, 2011
- Phacoemulsification versus phacoemulsification with micro-bypass stent implantation in primary open-angle glaucomaJournal of Cataract & Refractive Surgery, 2010
- Coexistent Primary Open-Angle Glaucoma and Cataract: Interim Analysis of a Trabecular Micro-Bypass Stent and Concurrent Cataract SurgeryEuropean Journal of Ophthalmology, 2009
- A Trabecular Bypass Flow HypothesisJournal of Glaucoma, 2005
- Global data on visual impairment in the year 2002.2004
- The effect of intraocular pressure on conventional outflow resistance in the enucleated human eye.1975
- Lens Depression and Aqueous Outflow in Enucleated Primate EyesAmerican Journal of Ophthalmology, 1973