Feasibility of long-distance heart rate monitoring using transmittance photoplethysmographic imaging (PPGI)
Open Access
- 6 October 2015
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 14637
Abstract
Photoplethysmography (PPG) devices are widely used for monitoring cardiovascular function. However, these devices require skin contact, which restricts their use to at-rest short-term monitoring. Photoplethysmographic imaging (PPGI) has been recently proposed as a non-contact monitoring alternative by measuring blood pulse signals across a spatial region of interest. Existing systems operate in reflectance mode, many of which are limited to short-distance monitoring and are prone to temporal changes in ambient illumination. This paper is the first study to investigate the feasibility of long-distance non-contact cardiovascular monitoring at the supermeter level using transmittance PPGI. For this purpose, a novel PPGI system was designed at the hardware and software level. Temporally coded illumination (TCI) is proposed for ambient correction and a signal processing pipeline is proposed for PPGI signal extraction. Experimental results show that the processing steps yielded a substantially more pulsatile PPGI signal than the raw acquired signal, resulting in statistically significant increases in correlation to ground-truth PPG in both short- "Equation missing" and long-distance "Equation missing" monitoring. The results support the hypothesis that long-distance heart rate monitoring is feasible using transmittance PPGI, allowing for new possibilities of monitoring cardiovascular function in a non-contact manner.Keywords
This publication has 22 references indexed in Scilit:
- Use of ambient light in remote photoplethysmographic systems: comparison between a high-performance camera and a low-cost webcamJournal of Biomedical Optics, 2012
- Photoplethysmographic imaging of high spatial resolutionBiomedical Optics Express, 2011
- Non-contact, automated cardiac pulse measurements using video imaging and blind source separationOptics Express, 2010
- Impaired Tissue PerfusionCirculation, 2008
- Noncontact simultaneous dual wavelength photoplethysmography: A further step toward noncontact pulse oximetryReview of Scientific Instruments, 2007
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- Contactless Multiple Wavelength Photoplethysmographic Imaging: A First Step Toward “SpO2 Camera” TechnologyAnnals of Biomedical Engineering, 2005
- An advanced detrending method with application to HRV analysisIEEE Transactions on Biomedical Engineering, 2002
- Heart rate variability: Origins, methods, and interpretive caveatsPsychophysiology, 1997
- A New Approach to Linear Filtering and Prediction ProblemsJournal of Basic Engineering, 1960