Comparison of ThinPrep versus conventional smear cytopreparatory techniques for fine-needle aspiration specimens of head and neck masses
Authors:
- 31 May 2002
- journal article
- clinical trial
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 126 (5) , 554-561
Abstract
OBJECTIVES: Diagnostic accuracy of the ThinPrep process (Cytyc, Boxborough, MA) was compared with that of conventional (smear) cytopreparation for fine-needle aspiration (FNA) of head and neck masses. METHODS: In a prospective, randomized, single-blinded study, 209 patients served as their own controls and underwent 236 FNAs using ThinPrep and conventional (smear) cytopreparatory techniques. RESULTS: ThinPrep produced less air-drying artifact and less mechanical distortion than the conventional method. The conventional technique was diagnostic in 63% of samples; the ThinPrep technique was diagnostic in 55% of samples. When all results were combined, pathologists subjectively preferred the conventional technique but accepted use of ThinPrep as the only cytopreparatory technique for most head and neck masses. CONCLUSIONS: For adequately experienced cytopathologists, ThinPrep is acceptable for FNA of salivary masses, neck cysts, metastatic lymph nodes, and thyroid lesions. Conventional smear technique should be used for FNA of nonmetastatic lymphoid lesions. Use of ThinPrep can complement use of the conventional (smear) cytopreparatory technique when aspirate is nondiagnostic or bloody, when the patient has a blood-borne infectious disease, when the clinician is inexperienced, or when aspirate has entered the syringe.Keywords
This publication has 10 references indexed in Scilit:
- Evaluation of the ThinPrep Processor for Fine Needle Aspiration SpecimensActa Cytologica, 1996
- ThinPrep Versus Conventional Smear Cytologic Preparations in the Analysis of Thyroid Fine-Needle Aspiration SpecimensAmerican Journal of Clinical Pathology, 1995
- Breast Fine-needle Aspiration:A Comparison of Thin-layer and Conventional PreparationAmerican Journal of Clinical Pathology, 1994
- Homogeneous Sampling Accounts for the Increased Diagnostic Accuracy Using the ThinPrep™ProcessorAmerican Journal of Clinical Pathology, 1994
- ThinPrep™Processor:Clinical Trials Demonstrate an Increased Detection Rate of Abnormal Cervical Cytologic SpecimensAmerican Journal of Clinical Pathology, 1994
- Fine-needle aspiration biopsy of head and neck lesionsJournal of Oral and Maxillofacial Surgery, 1991
- Fine needle aspiration cytology in the evaluation of head and neck massesThe American Journal of Surgery, 1990
- Fine needle aspiration cytology in the management ENT of patientsThe Journal of Laryngology & Otology, 1988
- Fine needle aspiration biopsyThe American Journal of Medicine, 1986
- Fine‐Needle aspiration biopsy revisited.The Laryngoscope, 1982