Objective. Invasive brain-computer interfaces (iBCIs) have evolved significantly since the first neurotrophic electrode was implanted in a human subject three decades ago. Since then, both hardware and software advances have increased the iBCI performance to enable tasks such as decoding conversations in real-time and manipulating external limb prostheses with haptic feedback. In this systematic review, we aim to evaluate the advances in iBCI hardware, software and functionality and describe challenges and opportunities in the iBCI field. Approach. Medline, EMBASE, PubMed and Cochrane databases were searched from inception until 13 April 2024. Primary studies reporting the use of iBCI in human subjects to restore function were included. Endpoints extracted include iBCI electrode type, iBCI implantation, decoder algorithm, iBCI effector, testing and training methodology and functional outcomes. Narrative synthesis of outcomes was done with a focus on hardware and software development trends over time. Individual patient data (IPD) was also collected and an IPD meta-analysis was done to identify factors significant to iBCI performance. Main results. 93 studies involving 214 patients were included in this systematic review. The median task performance accuracy for cursor control tasks was 76.00% (Interquartile range [IQR] = 21.2), for motor tasks was 80.00% (IQR = 23.3), and for communication tasks was 93.27% (IQR = 15.3). Current advances in iBCI software include use of recurrent neural network architectures as decoders, while hardware advances such as intravascular stentrodes provide a less invasive alternative for neural recording. Challenges include the lack of standardized testing paradigms for specific functional outcomes and issues with portability and chronicity limiting iBCI usage to laboratory settings. Significance. Our systematic review demonstrated the exponential rate at which iBCIs have evolved over the past two decades. Yet, more work is needed for widespread clinical adoption and translation to long-term home-use.Keywords
This publication has 136 references indexed in Scilit:
- A Review on Kalman Filter ModelsArchives of Computational Methods in Engineering, 2022
- Updated guidance for trusted systematic reviews: a new edition of the Cochrane Handbook for Systematic Reviews of InterventionsCochrane Database of Systematic Reviews, 2019
- A Critical Review of Microelectrode Arrays and Strategies for Improving Neural InterfacesAdvanced Healthcare Materials, 2019
- A review of electrodes for the electrical brain signal recordingBiomedical Engineering Letters, 2016
- Preferred Reporting Items for a Systematic Review and Meta-analysis of Individual Participant DataJAMA, 2015
- Brain-Computer Interface: Current and Emerging Rehabilitation ApplicationsArchives of Physical Medicine and Rehabilitation, 2015
- Long-Term Independent Brain-Computer Interface Home Use Improves Quality of Life of a Patient in the Locked-In State: A Case StudyArchives of Physical Medicine and Rehabilitation, 2015
- Silk as a Multifunctional Biomaterial Substrate for Reduced Glial Scarring around Brain‐Penetrating ElectrodesAdvanced Functional Materials, 2013
- Brain-Computer Interface (BCI): Types, Processing Perspectives and Applications2010
- A self-paced brain–computer interface for controlling a robot simulator: an online event labelling paradigm and an extended Kalman filter based algorithm for online trainingMedical & Biological Engineering & Computing, 2009