TEM Study of the Reaction Interface between an Apatite-Mullite Glass-Ceramic and Ti6Al4V
Authors:
- 20 November 2007
- journal article
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 361-363, 269-272
Abstract
Apatite-mullite glass-ceramics have been developed as an alternative to hydroxyapatite for use in vivo as a bioactive, osseoconductive biomedical alloy coating. In the cerammed state, they present a number of advantages including control over dissolution rates and mechanical properties by altering the composition of the parent glass or heat treatment regime. In the present study, a simple sedimentation route was used to coat a biomedical titanium alloy, commonly used for orthopaedic applications. The material was deposited as a glass and cerammed in situ to create a well adheared coating that resisted delamination or cracking. To investigate the nature of the coating-substrate reaction, a number of characterization techniques were used to examine the crystallization behaviour of the glass, the glass-ceramic microstructure, and the interfacial reaction region composition. The presence of products such as titanium silicides and unexpected pores are explained by proposed reaction routes between the titanium and glass coating.Keywords
This publication has 8 references indexed in Scilit:
- Real‐Time Nucleation and Crystallization Studies of a Fluorapatite Glass–Ceramics Using Small‐Angle Neutron Scattering and Neutron DiffractionJournal of the American Ceramic Society, 2007
- Crystallisation in apatite-mullite glass–ceramics as a function of fluorine contentJournal of Crystal Growth, 2005
- Physicochemical Degradation of Titania‐Stabilized Soluble Phosphate Glasses for Medical ApplicationsJournal of the American Ceramic Society, 2003
- Preparation of Calcium Phosphate Glass-Ceramics and their Coating on Titanium AlloysKey Engineering Materials, 2000
- The role of fluorine in the devitrification of SiO2·Al2O3·P2O5·CaO·CaF2 glassesJournal of Materials Science, 2000
- Glass-based coatings for titanium implant alloysJournal of Biomedical Materials Research, 1999
- Biocompatible and bioactive glass-ceramics — state of the art and new directionsJournal of Non-Crystalline Solids, 1997
- Apatite-mullite glass-ceramicsJournal of Non-Crystalline Solids, 1996