Technical Note: A fast and monolithic prototype clinical proton radiography system optimized for pencil beam scanning
- 4 February 2021
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 48 (3) , 1356-1364
Abstract
Purpose: To demonstrate a proton‐imaging system based on well‐established fast scintillator technology to achieve high performance with low cost and complexity, with the potential of a straightforward translation into clinical use.Methods: The system tracks individual protons through one (X, Y) scintillating fiber tracker plane upstream and downstream of the object and into a 13‐cm ‐thick scintillating block residual energy detector. The fibers in the tracker planes are multiplexed into silicon photomultipliers (SiPMs) to reduce the number of electronics channels. The light signal from the residual energy detector is collected by 16 photomultiplier tubes (PMTs). Only four signals from the PMTs are output from each event, which allows for fast signal readout. A robust calibration method of the PMT signal to residual energy has been developed to obtain accurate proton images. The development of patient‐specific scan patterns using multiple input energies allows for an image to be produced with minimal excess dose delivered to the patient.Results: The calibration of signals in the energy detector produces accurate residual range measurements limited by intrinsic range straggling. We measured the water‐equivalent thickness (WET) of a block of solid water (physical thickness of 6.10 mm) with a proton radiograph. The mean WET from all pixels in the block was 6.13 cm (SD 0.02 cm). The use of patient‐specific scan patterns using multiple input energies enables imaging with a compact range detector.Conclusions: We have developed a prototype clinical proton radiography system for pretreatment imaging in proton radiation therapy. We have optimized the system for use with pencil beam scanning systems and have achieved a reduction of size and complexity compared to previous designs.Keywords
All Related Versions
This publication has 10 references indexed in Scilit:
- Fast in situ image reconstruction for proton radiographyJournal of Radiation Oncology, 2019
- Regularised patient-specific stopping power calibration for proton therapy planning based on proton radiographic imagesPhysics in Medicine & Biology, 2019
- Design and characterisation of a real time proton and carbon ion radiography system based on scintillating optical fibresPhysica Medica, 2016
- Patient-specific stopping power calibration for proton therapy planning based on single-detector proton radiographyPhysics in Medicine & Biology, 2015
- Development of a head scanner for proton CTNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013
- TOPAS: An innovative proton Monte Carlo platform for research and clinical applicationsMedical Physics, 2012
- A detector system for proton radiography on the gantry of the Paul-Scherrer-InstituteNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- Proton radiography as a tool for quality control in proton therapyMedical Physics, 1995
- Patient positioning for protontherapy using a proton range telescopeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995
- Proton RadiographyScience, 1968