Improve matching ability of stent and balloon via preparing nano-structure by low-temperature plasma treatment
- 24 March 2017
- journal article
- research article
- Published by Taylor & Francis in Integrated Ferroelectrics
- Vol. 179 (1) , 24-30
Abstract
The matching ability between stent and balloon is an important property to the trackability and crossibility of delivering system; it's also influence the flexibility of operation in clinic. In this work, the low-temperature plasma sputtering method was employed to prepare nano-structure on balloon surface, the matching properties were investigated via the removing force, compliance and aging test; the micro-morphous was also characterized by scanning electron microscope. The result indicates that the removing force of the sputtered balloon is obviously increased comparing to un-treated that, and the compliance of both balloon catheters is similar, but the lower-temperature plasma treated balloon is more preferable than that of untreated that through aging test results. The distribution of stent struts on balloon surface is more uniform than untreated surface, and the deformation and fold of treated surface wasn't found, which indicates that the matching ability between stent and balloon would be enhance via low-temperature plasma sputtering.Keywords
This publication has 10 references indexed in Scilit:
- Mechanical behavior and blood compatibility of copper-containing films as potential biomaterialsBio-Medical Materials and Engineering, 2015
- A rare instructive complication of balloon catheter fracture during percutaneous coronary interventionCardiovascular Intervention and Therapeutics, 2015
- A novel steerable Foley balloon catheter for preventing phrenic nerve injury during epicardial catheter ablationJournal of Interventional Cardiac Electrophysiology, 2014
- Influence of a paclitaxel coated balloon in combination with a bare metal stent on restenosis and endothelial function: Comparison with a drug eluting stent and a bare metal stentCatheterization and Cardiovascular Interventions, 2013
- In vivo distribution of particulate matter from coated angioplasty balloon cathetersBiomaterials, 2013
- Combined use of a double-lumen remodeling balloon and a low-profile stent in the treatment of intracranial aneurysms (‘remostent’ technique): A technical noteJournal Of Neuroradiology, 2013
- Better stent expansion by two-time inflation of stent balloon and its responsible mechanismJournal of Cardiology, 2012
- Review of Randomized Clinical Trials of Drug-Eluting Stents for the Prevention of In-Stent Restenosis††All study acronyms used in this review are defined in Table 1.The American Journal of Cardiology, 2006
- An Avoidable Complication of Percutaneous Coronary Intervention—Entrapment of Stent and Disconnected Balloon CatheterThe Kaohsiung Journal of Medical Sciences, 2006
- Effect of increased intra-aortic balloon pressure on catheter volumeCritical Care Medicine, 1992