Bidirectional Peripheral Nerve Interface With 64 Second-Order Opamp-Less ΔΣ ADCs and Fully Integrated Wireless Power/Data Transmission
- 1 October 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56 (11) , 3247-3262
Abstract
An active probe and microstimulator SoC for interfacing with peripheral nerves is presented. It performs 64-channel artifact-tolerant neural recording, cuff imbalance compensation by impedance sensing, and neurostimulation for the closed-loop operation. Each recording channel is a second-order opamp-less $\Delta \Sigma $ ADC that consumes 140 nW and occupies 0.01 mm 2 area in 130 nm CMOS. The single-loop $\Delta \Sigma $ architecture achieves second-order noise shaping with two passive integrators. To the best of our knowledge, this yields the lowest power and area of any second-order $\Delta \Sigma $ ADC and the lowest FOM (fJ/conv. step) of any passive second-order $\Delta \Sigma $ ADC (27 fJ/conv. step). The SoC uniquely performs multi-modal input signal recording: voltage (for neural recording) and current (for impedance sensing) are measured concurrently using frequency multiplexing. The SoC also features a 60 MHz energy-efficient inductive powering link and a 600 MHz RF data communication link. The prototype is validated in vivo in the rat sciatic nerve for electroneurogram (ENG) sensing and the correction of impedance-imbalance in cuff electrodes.
Keywords
Funding Information
- Natural Sciences and Engineering Research Council (NSERC) of Canada
- Canada Foundation for Innovation
This publication has 39 references indexed in Scilit:
- Nanostructured CMOS Wireless Ultra-Wideband Label-Free PCR-Free DNA Analysis SoCIEEE Journal of Solid-State Circuits, 2014
- Low-Power DT $\Delta \Sigma$ Modulators Using SC Passive Filters in 65 nm CMOSIEEE Transactions on Circuits and Systems I: Regular Papers, 2013
- A jump-start for electroceuticalsNature, 2013
- On Cuff Imbalance and Tripolar ENG Amplifier ConfigurationsIEEE Transactions on Biomedical Engineering, 2005
- Skin contact forces extracted from human nerve signals-a possible feedback signal for FES-aided control of standingIEEE Transactions on Biomedical Engineering, 2003
- Artefact reduction with alternative cuff configurationsIEEE Transactions on Biomedical Engineering, 2003
- Real Time Foot Drop Correction using Machine Learning and Natural SensorsNeuromodulation: Technology at the Neural Interface, 2002
- A 0.25-mW low-pass passive sigma-delta modulator with built-in mixer for a 10-MHz IF inputIEEE Journal of Solid-State Circuits, 1997
- Natural neural sensing and artificial muscle control in manExperimental Brain Research, 1994
- Fiber composition of the rat sciatic nerveThe Anatomical Record, 1986