Diagnostic Reference Levels (DRLs) and Image Quality Evaluation for Digital Mammography in a Nigerian Facility
Authors:
Open Access
- 29 May 2022
- journal article
- research article
- Published by Nigerian Society of Physical Sciences in Journal of the Nigerian Society of Physical Sciences
- p. 281-286
Abstract
Diagnostic Reference Levels (DRLs) for digital mammography and image quality evaluation are important optimization tools in medical imaging. High quality mammograms are essential to the successful early detection of breast cancer. The objective of the study is to establish DRLs for digital mammography and to assess image quality of the mammograms for optimization. DRLs were established using thermoluminescent dosimeter (TLD) chips to estimate the mean glandular dose for both cranio-caudal and medio-lateral oblique projections. The TLD chips were calibrated. The DRLs were set at the 75th percentile of the distribution of the median value of mean glandular dose. Image quality was assessed using European Commission guideline for mammographic image quality assessment. Results for DRLs were 0.53 mGy for cranio-caudal and also 0.53 mGy for medio-lateral oblique. Image quality evaluation showed criteria scores for cranio-caudal and medio-lateral oblique projections as 76 % and 61.2 % respectively. The mammograms scored the highest and lowest score of 100 % and 44 % on criteria 2 and criteria 6 (absence of skin fold) respectively for cranio-caudal projections while for the mediolateral oblique projections, criteria 1 (all breast tissue clearly shown) and criteria 5 (inframammary angle clearly demonstrated) have the highest and lowest score of 96 % and 8 % respectively. The study showed that the DRLs in this study was lower than the established values in other regions of Nigeria and international established values. Image quality was within acceptable level. DRLs for digital mammography and image quality evaluation are important optimization tool that should be adopted by every radiology department with mammography unit.Keywords
This publication has 9 references indexed in Scilit:
- Diagnostic reference levels for mammography examinations in North Eastern NigeriaAfrican Journal of Medical and Health Sciences, 2018
- ICRP Publication 135: Diagnostic Reference Levels in Medical ImagingAnnals of the ICRP, 2017
- Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocolsPhysics in Medicine & Biology, 2010
- Mean glandular doses for women undergoing mammographic breast screening in Oyo state, NigeriaRadiography, 2009
- Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA breast dosimetry protocolsPhysics in Medicine & Biology, 2009
- Screening MammographyAmerican Journal of Roentgenology, 2002
- Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocolPhysics in Medicine & Biology, 2000
- Radiological protection and safety in medicineAnnals of the ICRP, 1996
- Monte-Carlo calculation of conversion factors for the estimation of mean glandular breast dosePhysics in Medicine & Biology, 1990