A novel noninvasive approach for evaluating work of breathing indices in a developmental rat model using respiratory inductance plethysmography
Open Access
- 26 November 2020
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-7
Abstract
Pulmonary function testing (PFT) is an important component for evaluating the outcome of experimental rodent models of respiratory diseases. Respiratory inductance plethysmography (RIP) provides a noninvasive method of PFT requiring minimal cooperation. RIP measures work of breathing (WOB) indices including phase angle (Ф), percent rib cage (RC %), breaths per minute (BPM), and labored breathing index (LBI) on an iPad. The aim of this study was to evaluate the utility of a recently developed research instrument, pneuRIP, for evaluation of WOB indices in a developmental rat model. Sprague Dawley rats (2 months old) were commercially acquired and anaesthetised with isoflurane. The pneuRIP system uses two elastic bands: one band (RC) placed around the rib cage under the upper armpit and another band (AB) around the abdomen. The typical thoracoabdominal motion (TAM) plot showed the abdomen and rib cage motion in synchrony. The plots of phase angle and LBI as a function of data point number showed that values were within the range. The distribution for phase angle and LBI was within a narrow range. pneuRIP testing provided instantaneous PFT results. This study demonstrated the utility of RIP as a rapid, noninvasive approach for evaluating treatment interventions in the rodent model.Keywords
Funding Information
- The Nemours Foundation
- University of Delaware, Center for Advanced Technology (CAT) Program (44058)
- Institutional Development Award (IDeA) from the National Institute of General Medical Sciences of the National Institutes of Health (NIH COBRE P30GM114736)
This publication has 21 references indexed in Scilit:
- Work of breathing indices in infants with respiratory insufficiency receiving high-flow nasal cannula and nasal continuous positive airway pressureJournal of Perinatology, 2013
- Pulmonary Function Tests in Emergency Department Pediatric Patients with Acute Wheezing/Asthma ExacerbationPulmonary Medicine, 2012
- Idade dos ratos versus idade humana: qual é a relação?ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo), 2012
- Lung Function Measurements in Rodents in Safety Pharmacology StudiesFrontiers in Pharmacology, 2012
- Surfactant administration prior to one lung ventilation: Physiological and inflammatory correlates in a piglet modelPediatric Pulmonology, 2011
- Skeletal dysplasias: Evaluation with impulse oscillometry and thoracoabdominal motion analysisPediatric Pulmonology, 2010
- Chest wall motion in preterm infants using respiratory inductive plethysmographyEuropean Respiratory Journal, 1997
- Characteristic modifications of the breathing pattern of mice to evaluate the effects of airborne chemicals on the respiratory tractArchives of Toxicology, 1993
- Chest wall motion before and during mechanical ventilation in children with neuromuscular diseasePediatric Pulmonology, 1993
- Interaction between chest wall motion and lung mechanics in normal infants and infants with bronchopulmonary dysplasiaPediatric Pulmonology, 1991