Self-Collected Oral Fluid Saliva Is Insensitive Compared With Nasal-Oropharyngeal Swabs in the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 in Outpatients
Open Access
- 30 December 2020
- journal article
- research article
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 8 (2) , ofaa648
Abstract
Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic control will require widespread access to accurate diagnostics. Salivary sampling circumvents swab supply chain bottlenecks, is amenable to self-collection, and is less likely to create an aerosol during collection compared with the nasopharyngeal swab. Methods: We compared real-time reverse-transcription polymerase chain reaction Abbott m2000 results from matched salivary oral fluid (gingival crevicular fluid collected in an Oracol device) and nasal-oropharyngeal (OP) self-collected specimens in viral transport media from a nonhospitalized, ambulatory cohort of coronavirus disease 2019 (COVID-19) patients at multiple time points. These 2 sentences should be at the beginning of the results. Results: There were 171 matched specimen pairs. Compared with nasal-OP swabs, 41.6% of the oral fluid samples were positive. Adding spit to the oral fluid percent collection device increased the percent positive agreement from 37.2% (16 of 43) to 44.6% (29 of 65). The positive percent agreement was highest in the first 5 days after symptoms and decreased thereafter. All of the infectious nasal-OP samples (culture positive on VeroE6 TMPRSS2 cells) had a matched SARS-CoV-2 positive oral fluid sample. Conclusions: In this study of nonhospitalized SARS-CoV-2-infected persons, we demonstrate lower diagnostic sensitivity of self-collected oral fluid compared with nasal-OP specimens, a difference that was especially prominent more than 5 days from symptom onset. These data do not justify the routine use of oral fluid collection for diagnosis of SARS-CoV-2 despite the greater ease of collection. It also underscores the importance of considering the method of saliva specimen collection and the time from symptom onset especially in outpatient populations.Keywords
Funding Information
- Johns Hopkins University School of Medicine COVID-19 Research Fund
- Sherrilyn and Ken Fisher Center for Environmental Infectious Diseases Discovery Program
- National Institutes of Health (U54EB007958-12, U5411090366, U54HL143541-02S2, UM1AI068613)
This publication has 32 references indexed in Scilit:
- Saliva as a Noninvasive Specimen for Detection of SARS-CoV-2Journal of Clinical Microbiology, 2020
- Validation of SARS-CoV-2 detection across multiple specimen typesJournal of Clinical Virology, 2020
- Saliva is a reliable tool to detect SARS-CoV-2Journal of Infection, 2020
- Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort studyThe Lancet Infectious Diseases, 2020
- An interactive web-based dashboard to track COVID-19 in real timeThe Lancet Infectious Diseases, 2020
- Enhanced isolation of SARS-CoV-2 by TMPRSS2-expressing cellsProceedings of the National Academy of Sciences of the United States of America, 2020
- Consistent Detection of 2019 Novel Coronavirus in SalivaClinical Infectious Diseases, 2020
- Clinical features of patients infected with 2019 novel coronavirus in Wuhan, ChinaThe Lancet, 2020
- Development of the Flu-PRO: a patient-reported outcome (PRO) instrument to evaluate symptoms of influenzaBMC Infectious Diseases, 2015
- Comparison of Flocked and Rayon Swabs for Collection of Respiratory Epithelial Cells from Uninfected Volunteers and Symptomatic PatientsJournal of Clinical Microbiology, 2006